M2488 PRODUCT GUIDE

MTU DIAGNOSTIC SPECIFICATIONS

ERROR RESET

 

:

name

:

code

DIAG command code

:

ERROR RESET command

:

0x70 or 0xF0

 

 

 

 

 

DIAG parameter 1

:

 

:

 

 

 

 

 

 

DIAG parameter 2

:

 

:

 

 

 

 

 

 

DIAG parameter 3

:

 

:

 

 

 

 

 

 

DIAG parameter 4

:

 

:

 

 

 

 

 

 

DIAG parameter 5

:

 

:

 

 

 

 

 

 

DIAG parameter 6

:

 

:

 

 

 

 

 

 

DIAG parameter 7

:

 

:

 

 

 

 

 

 

DIAG parameter 8

:

 

:

 

 

 

 

 

 

DIAG parameter 9

:

 

:

 

 

 

 

 

 

execute time

:

 

:

 

 

 

 

 

 

stop time

:

 

:

 

 

 

 

 

 

execute count

:

 

:

 

 

 

 

 

 

reserve

:

 

:

 

 

 

 

 

 

H-6 DIAG RESULT DATA

The MTU DIAG execution result takes up 512 bytes.

Explanation

The DIAG execution result data is divided into groups. Each group requires 32 bytes. The result data is stored in an area corresponding to the DIAG group executed under the SEND DIAGNOSTIC command.

struct diag result {

unsigned short error code;

unsigned short diag result data[15];

}diag output parm [16]; error code : 0x0000 ------ Normal end error code : 0xFF00 ------ Break end

error code : 0x00XX ------ Error end ( XX : Error code )

The DIAG result data format is shown as follows:

DIAG result format

Result of Loading time (“M1:LOAD”)

 

 

:

measurement result

: unit

 

 

 

 

 

0- 1

error code

:

 

:

 

 

 

 

 

2- 3

result data 1

:

Loading time

: 1/10 sec

 

 

 

 

 

4- 5

result data 2

:

Clutch winding time

: 1/10 sec

 

 

 

 

 

6- 7

result data 3

:

Threading time

: 1/10 sec

 

 

 

 

 

8- 9

result data 4

:

BOT shaking time for normal CTG

: 1/10 sec

 

 

 

 

 

10- 11

result data 5

:

BOT shaking time for E-CTG

: 1/10 sec

 

 

 

 

 

12- 13

result data 6

:

 

:

 

 

 

 

 

14- 15

result data 7

:

 

:

 

 

 

 

 

April 1997

CG00000-011503 REV. A