DIAGNOSTIC TESTS AND ERROR CODES M2488 PRODUCT GUIDE
F-72 CG00000-011503 REV. A April 1997Table F-20. Routine 80 Test 06 - Servo ACL Error Codes in Sense Byte 19
ROUTINE TEST TITLE ERROR
CODE DESCRIPTION
0x80 0x06 Sense Byte 19 for ACL 0x01 Bottom stopper up and down sensors both on
0x02 Bottom stopper up too fast
0x03 Bottom stopper up too slow (or not move)
0x04 Bottom stopper down too fast
0x05 Bottom stopper down too slow (or not move)
0x10 Pinion phase sensor always on
0x11 Magazine motor move up too fast
0x12 Magazine motor move up too slow (or not
move)
0x13 Magazine motor move down too fast
0x14 Magazine motor move down too slow (or not
move)
0x20 Feeder arm open and close sensors both on
0x21 Catcher open too fast
0x22 Catcher open too slow (or not move)
0x23 Catcher close too fast
0x24 Catcher close too slow (or not move)
0x30 Mount arm home sensor always on
0x31 Mount arm move forward too slow
0x40 Magazine is detected
0x50 Cartridge inverse check
0x60 Pushed interlock check
0x70 Cartridge is detected
DIAGNOSTIC TESTS