DIAGNOSTIC TESTS AND ERROR CODES

M2488 PRODUCT GUIDE

DIAGNOSTIC TESTS AND ERROR CODES

Table F-20. Routine 80 Test 06 - Servo ACL Error Codes in Sense Byte 19

ROUTINE

TEST

TITLE

ERROR

DESCRIPTION

CODE

 

 

 

 

 

 

 

 

 

0x80

0x06

Sense Byte 19 for ACL

0x01

Bottom stopper up and down sensors both on

 

 

 

 

 

 

 

 

0x02

Bottom stopper up too fast

 

 

 

 

 

 

 

 

0x03

Bottom stopper up too slow (or not move)

 

 

 

 

 

 

 

 

0x04

Bottom stopper down too fast

 

 

 

 

 

 

 

 

0x05

Bottom stopper down too slow (or not move)

 

 

 

 

 

 

 

 

0x10

Pinion phase sensor always on

 

 

 

 

 

 

 

 

0x11

Magazine motor move up too fast

 

 

 

 

 

 

 

 

0x12

Magazine motor move up too slow (or not

 

 

 

 

move)

 

 

 

 

 

 

 

 

0x13

Magazine motor move down too fast

 

 

 

 

 

 

 

 

0x14

Magazine motor move down too slow (or not

 

 

 

 

move)

 

 

 

 

 

 

 

 

0x20

Feeder arm open and close sensors both on

 

 

 

 

 

 

 

 

0x21

Catcher open too fast

 

 

 

 

 

 

 

 

0x22

Catcher open too slow (or not move)

 

 

 

 

 

 

 

 

0x23

Catcher close too fast

 

 

 

 

 

 

 

 

0x24

Catcher close too slow (or not move)

 

 

 

 

 

 

 

 

0x30

Mount arm home sensor always on

 

 

 

 

 

 

 

 

0x31

Mount arm move forward too slow

 

 

 

 

 

 

 

 

0x40

Magazine is detected

 

 

 

 

 

 

 

 

0x50

Cartridge inverse check

 

 

 

 

 

 

 

 

0x60

Pushed interlock check

 

 

 

 

 

 

 

 

0x70

Cartridge is detected

 

 

 

 

 

F-72