DIAGNOSTIC TESTS AND ERROR CODES M2488 PRODUCT GUIDE
F-58 CG00000-011503 REV. A April 1997
0x20 0x0A LWR2 - ETPs - Unknown Error -
36 Track 0x40 RSVP did not respond while looking for
DBOB or IBG.
0x20 0x0B LWR2 - ETPs - Unknown Error -
18 Track 0x20 RSVP failed to Respond
0x21 DATA Xreg Miscompare - RSVP not Ready
0x22 DATB Xreg Miscompare - RSVP not Ready
0x23 FHC1 time-out - DBOB not detected by
RSVP
0x24 FLC0 time-out - RSVP detected Long IBG
0x25 FHC2 or FLC2 Time Out - Slow End of Data
Block
0x26 Lost DBOB prior to PHOK or while waiting
for DPOST
0x27 PHOK not seen in time
0x28 Time-out waiting for DPRE
0x29 Lost DBOB waiting for DPRE
0x2A Time-out waiting for DPOST
0x2B PHOK on after Read End
0x2C RSVP Dead Man time-out
0x2D Last Blk not Found
0x2E RSVP error - RSVP failed, cause unknown
0x2F IBG active, should not be - check INLWR
pulled high.
0x40 RSVP did not respond while looking for
DBOB or IBG.
0x20 0x0C LWR2 - Ignore Invalid ETP - 4
good fms 0x20 RSVP failed to Respond
0x21 DATA Xreg Miscompare - RSVP not Ready
0x22 DATB Xreg Miscompare - RSVP not Ready
0x23 FHC1 time-out - DBOB not detected by
RSVP
0x24 FLC0 time-out - RSVP detected Long IBG
0x25 FHC2 or FLC2 Time Out - Slow End of Data
Block
0x26 Lost DBOB prior to PHOK or while waiting
for DPOST
Table F-16. Routine 20 - Loop Write to Read Diagnostic Error Codes (Continued)
ROUTINE TEST TITLE ERROR
CODE DESCRIPTION
DIAGNOSTIC TESTS
AND ERROR CODES