DIAGNOSTIC TESTS AND ERROR CODES

DIAGNOSTIC TESTS AND ERROR CODES

 

M2488 PRODUCT GUIDE

Table F-15. Routine 13 - EDRC Error Detection Diagnostic Error Codes (Continued)

 

 

 

 

 

ROUTINE

TEST

TITLE

ERROR

DESCRIPTION

CODE

 

 

 

 

 

 

 

 

 

0x13

0x02

Read Hi_data parity error check

0x09

The SPC interrupt request could not be

 

 

 

 

cleared

 

 

 

 

 

0x13

0x03

Read Sync host crc error check

0x01

Failed to receive data end-of-transfer signal in

 

 

 

 

SDDP hdxs register.

 

 

 

 

 

 

 

 

0x02

Incorrect SPC SCSI control signal status wait-

 

 

 

 

ing for REQ signal assertion.

 

 

 

 

 

 

 

 

0x03

Incorrect SPC SCSI control signal status wait-

 

 

 

 

ing for REQ signal deassertion.

 

 

 

 

 

 

 

 

0x04

Data transfer length error reported by SPC

 

 

 

 

 

 

 

 

0x05

SDDP failed to report expected CRC error.

 

 

 

 

 

0x13

0x04

Write Buffer overflow error check

0x01

Initial SPC write status is incorrect.

 

 

 

 

 

 

 

 

0x02

Error reported by Record Manager Write

 

 

 

 

Buffer function while attempting to write

 

 

 

 

clear SG-bypass.

 

 

 

 

 

 

 

 

0x03

Incorrect SPC SCSI control signal status wait-

 

 

 

 

ing for REQ signal assertion.

 

 

 

 

 

 

 

 

0x04

Incorrect SPC SCSI control signal status wait-

 

 

 

 

ing for REQ signal deassertion.

 

 

 

 

 

 

 

 

0x05

Data transfer length error reported by SPC

 

 

 

 

 

 

 

 

0x06

SDDP failed to report expected buffer over-

 

 

 

 

flow.

 

 

 

 

 

0x13

0x05

Read crc-b error check

0x01

Failed to receive data end-of-transfer signal in

 

 

 

 

SDDP hdxs register.

 

 

 

 

 

 

 

 

0x02

Incorrect SPC SCSI control signal status wait-

 

 

 

 

ing for REQ signal assertion.

 

 

 

 

 

 

 

 

0x03

Incorrect SPC SCSI control signal status wait-

 

 

 

 

ing for REQ signal deassertion.

 

 

 

 

 

 

 

 

0x04

Data transfer length error reported by SPC

 

 

 

 

 

 

 

 

0x05

SDDP failed to report expected CRC-B error.

 

 

 

 

 

0x13

0x06

Read header crc error check

0x01

Failed to receive data end-of-transfer signal in

 

 

 

 

SDDP hdxs register.

 

 

 

 

 

 

 

 

0x02

Incorrect SPC SCSI control signal status wait-

 

 

 

 

ing for REQ signal assertion.

 

 

 

 

 

 

 

 

0x03

Incorrect SPC SCSI control signal status wait-

 

 

 

 

ing for REQ signal deassertion.

 

 

 

 

 

 

 

 

0x04

Data transfer length error reported by SPC

 

 

 

 

 

 

 

 

0x05

SDDP failed to report expected header CRC

 

 

 

 

error.

 

 

 

 

 

F-46

CG00000-011503 REV. A

April 1997

Page 446
Image 446
Fujitsu M2488 manual Diagnostic Tests and Error Codes