M2488 PRODUCT GUIDE

 

DIAGNOSTIC TESTS AND ERROR CODES

Table F-6. Routine 4 - Read Signal Verification Processor Diagnostic Error Codes (Continued)

 

 

 

 

 

ROUTINE

TEST

TITLE

ERROR

DESCRIPTION

CODE

 

 

 

 

 

 

 

 

 

 

0x04

0x07

RSVP Counters test - single byte

0x0A

 

Timeout waiting for Response Available after

 

 

mode

 

 

setting CECC Order Available testing counter

 

 

 

 

 

2, high byte carry out

 

 

 

 

 

 

 

 

 

0x0B

 

RSVP Interrupts not set as expected testing

 

 

 

 

 

counter 2, high byte carry out

 

 

 

 

 

 

 

 

 

0x0C

 

Register CECC data miscompare after reset-

 

 

 

 

 

ting Response Available testing counter 2,

 

 

 

 

 

high byte carry out

 

 

 

 

 

 

 

 

 

0x0D

 

Timeout waiting for Response Available after

 

 

 

 

 

setting CECC Order Available testing counter

 

 

 

 

 

1, high byte carry out

 

 

 

 

 

 

 

 

 

0x0E

 

RSVP Interrupts not set as expected testing

 

 

 

 

 

counter 1, high byte carry out

 

 

 

 

 

 

 

 

 

0x0F

 

Register CECC data miscompare after reset-

 

 

 

 

 

ting Response Available testing counter 1,

 

 

 

 

 

high byte carry out

 

 

 

 

 

 

 

 

 

0x10

 

Timeout waiting for Response Available after

 

 

 

 

 

setting CECC Order Available testing counter

 

 

 

 

 

0, high byte carry out

 

 

 

 

 

 

 

 

 

0x11

 

RSVP Interrupts not set as expected testing

 

 

 

 

 

counter 0, high byte carry out

 

 

 

 

 

 

 

 

 

0x12

 

Register CECC data miscompare after reset-

 

 

 

 

 

ting Response Available testing counter 0,

 

 

 

 

 

high byte carry out

 

 

 

 

 

 

0x04

0x08

RSVP Counters test - 2 byte mode

0x01

 

Timeout waiting for Response Available after

 

 

 

 

 

setting CECC Order Available testing counter

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

0x02

 

RSVP Interrupts not set as expected testing

 

 

 

 

 

counter 2

 

 

 

 

 

 

 

 

 

0x03

 

Register CECC data miscompare after reset-

 

 

 

 

 

ting Response Available testing counter 2

 

 

 

 

 

 

 

 

 

0x04

 

Timeout waiting for Response Available after

 

 

 

 

 

setting CECC Order Available testing counter

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

0x05

 

RSVP Interrupts not set as expected testing

 

 

 

 

 

counter 1

 

 

 

 

 

 

 

 

 

0x06

 

Register CECC data miscompare after reset-

 

 

 

 

 

ting Response Available testing counter 1

 

 

 

 

 

 

 

 

 

0x07

 

Timeout waiting for Response Available after

 

 

 

 

 

setting CECC Order Available testing counter

 

 

 

 

 

0

 

 

 

 

 

 

DIAGNOSTIC TESTS AND ERROR CODES

April 1997

CG00000-011503 REV. A

F-17

Page 417
Image 417
Fujitsu M2488 manual Diagnostic Tests and Error Codes