M2488 PRODUCT GUIDE

 

DIAGNOSTIC TESTS AND ERROR CODES

 

Table F-10. Routine 8 - Formatter Counters Diagnostic Error Codes (Continued)

 

 

 

 

 

 

ROUTINE

 

TEST

TITLE

ERROR

DESCRIPTION

 

CODE

 

 

 

 

 

 

 

 

 

 

 

 

0x08

 

0x01

Formatter Counter 0 test

0x0A

 

The low byte count for Formatter Counter 0

 

 

 

 

 

 

did not contain the expected value after the

 

 

 

 

 

 

counter finished running

 

 

 

 

 

 

 

 

 

 

 

0x0B

 

Test Jump Carry Out bit for the low byte

 

 

 

 

 

 

count of Formatter Counter 0 was not set as

 

 

 

 

 

 

expected after the counter finished running

 

 

 

 

 

 

 

 

 

 

 

0x0C

 

WBEND_CNEH0 Interrupt not set as

 

 

 

 

 

 

expected

 

 

 

 

 

 

 

0x08

 

0x02

Formatter Counter 1 test

0x01

 

The Formatter Counter 1 count enable register

 

 

 

 

 

 

could not be cleared

 

 

 

 

 

 

 

 

 

 

 

0x02

 

A data miscompare occurred walking a one

 

 

 

 

 

 

through the Formatter Counter 1 high byte

 

 

 

 

 

 

count register

 

 

 

 

 

 

 

 

 

 

 

0x03

 

A data miscompare occurred walking a one

 

 

 

 

 

 

through the Formatter Counter 1 low byte

 

 

 

 

 

 

count register

 

 

 

 

 

 

 

 

 

 

 

0x04

 

Test Jump Carry Out bit for the high byte

 

 

 

 

 

 

count of Formatter Counter 1 was set prema-

 

 

 

 

 

 

turely before counter was started

 

 

 

 

 

 

 

 

 

 

 

0x05

 

An unexpected value was read in the count

 

 

 

 

 

 

enable register for Formatter Counter 1 after

 

 

 

 

 

 

the high byte counter finished running

 

 

 

 

 

 

 

 

 

 

 

0x06

 

The high byte count for Formatter Counter 1

 

 

 

 

 

 

did not contain the expected value after the

 

 

 

 

 

 

counter finished running

 

 

 

 

 

 

 

 

 

 

 

0x07

 

Test Jump Carry Out bit for the high byte

 

 

 

 

 

 

count of Formatter Counter 1 was not set as

 

 

 

 

 

 

expected after the counter finished running

 

 

 

 

 

 

 

 

 

 

 

0x08

 

Test Jump Carry Out bit for the low byte

 

 

 

 

 

 

count of Formatter Counter 1 was set prema-

 

 

 

 

 

 

turely before counter was started

 

 

 

 

 

 

 

 

 

 

 

0x09

 

An unexpected value was read in the count

 

 

 

 

 

 

enable register for Formatter Counter 1 after

 

 

 

 

 

 

the low byte counter finished running

 

 

 

 

 

 

 

 

 

 

 

0x0A

 

The low byte count for Formatter Counter 1

 

 

 

 

 

 

did not contain the expected value after the

 

 

 

 

 

 

counter finished running

 

 

 

 

 

 

 

 

 

 

 

0x0B

 

Test Jump Carry Out bit for the low byte

 

 

 

 

 

 

count of Formatter Counter 1 was not set as

 

 

 

 

 

 

expected after the counter finished running

 

 

 

 

 

 

 

0x08

 

0x03

Formatter Counter 2 test

0x01

 

The Formatter Counter 2 count enable register

 

 

 

 

 

 

could not be cleared

 

 

 

 

 

 

 

DIAGNOSTIC TESTS AND ERROR CODES

April 1997

CG00000-011503 REV. A

F-23

Page 423
Image 423
Fujitsu M2488 manual Diagnostic Tests and Error Codes