TAPE UNIT SCSI COMMANDS M2488 PRODUCT GUIDE
4-100 CG00000-011503 REV. A April 19974-3.21.4 RECOVER BUFFER ED DATA Sens e Keys
One of the following sense keys may be returned if a CHECK CONDITION was indicated:
SENSE KEY CONDITION DESCRIPTION
0h NO SENSE 1. SILI and Fixed bits are both zero and the actual length of the
block transferred is different from the specified Transfer length
field of the CDB.
2. Filemark encountered during the recover buffered data opera-
tion.
3. More blocks are requested to be transferred than are contained
in the buffer
4h HARDWARE ERROR Transfer of data to initiator failed due to hardware failure
5h ILLEGAL REQUEST 1. Reserved bit was found set in the CDB.
2. The Fixed bit was set to one, but the current mode is variable
(as defined by the current Mode Select state).
3. The SILI and Fixed bits are both set to one.
4. The Flag bit was set but the Link bit was not set.
6h UNIT ATTENTION Indicates the RECOVER BUFFERED DATA command was not
performed due to one of the following:
1. The tape cartridge may have been changed.
2. The target has been reset.
3. The Mode parameters have been changed by another initiator.
4. The version of the microcode has been changed (microcode
downloaded).
5. A cartridge was loaded with a tape length that is too long or too
short.
Bh ABORTED COMMAND RECOVER BUFFERED DATA command was aborted
Dh VOLUME OVERFLOW Write of buffered data prior to the RECOVER BUFFERED
DATA operation failed because physical End-of-Tape has been
reached.