DIAGNOSTIC TESTS AND ERROR CODES M2488 PRODUCT GUIDE
F-38 CG00000-011503 REV. A April 1997Table F-14. Routine 12 - EDRC Address Bus Diagnostic Error Codes
ROUTINE TEST TITLE ERROR
CODE DESCRIPTION
0x12 * All R20 Address Check Diagnos-
tics 0xD0 SPC register initialization failed
0xE0 SPC did not generate an interrupt request
0xE1 SPC interrupt was not detected at the Interrupt
Request Controller
0xE2 The SPC interrupt was cleared while clearing
the Interrupt Request Controller.
0xE3 SPC interrupt/step code did not report Com-
mand Complete
0xE4 The SPC interrupt request could not be
cleared
0xE5 SPC did not generate an interrupt request
0xE6 SPC interrupt was not detected at the Interrupt
Request Controller
0xE7 The SPC interrupt was cleared while clearing
the Interrupt Request Controller.
0xE8 SPC interrupt/step code did not report Diag-
nostic Self-Test passed
0xE9 The SPC interrupt request could not be
cleared
0x10 At end of test, SPC did not generate an inter-
rupt request.
0x11 At end of test, SPC interrupt was not detected
at the Interrupt Request Controller.
0x12 At end of test, the SPC interrupt was cleared
while clearing the Interrupt Request Control-
ler.
0x13 At end of test, SPC interrupt/step code did not
report Command Complete.
0x14 At end of test, the SPC interrupt request could
not be cleared.
0xEF SPC interrupt request or interrupt/step register
could not be cleared at the end of the test
0x12 0x01 SDDP-R20 buffer flush signal
test, mode 14h 0x01 after a write diag operation was initialized in
the spc chip, the SPC-status register did not
have one of the following:
SPC_data_trans_rdy, SPC_busy, or
SPC_data_reg_empty.
0x02 A non SUCCESS status was returned from
the function call rm_request_wrtbuffer.
DIAGNOSTIC TESTS
AND ERROR CODES