DIAGNOSTIC TESTS AND ERROR CODES

DIAGNOSTIC TESTS AND ERROR CODES

 

M2488 PRODUCT GUIDE

 

Table F-14. Routine 12 - EDRC Address Bus Diagnostic Error Codes

 

 

 

 

 

ROUTINE

TEST

TITLE

ERROR

DESCRIPTION

CODE

 

 

 

 

 

 

 

 

 

0x12

*

All R20 Address Check Diagnos-

0xD0

SPC register initialization failed

 

 

tics

 

 

 

 

 

 

 

 

 

 

0xE0

SPC did not generate an interrupt request

 

 

 

 

 

 

 

 

0xE1

SPC interrupt was not detected at the Interrupt

 

 

 

 

Request Controller

 

 

 

 

 

 

 

 

0xE2

The SPC interrupt was cleared while clearing

 

 

 

 

the Interrupt Request Controller.

 

 

 

 

 

 

 

 

0xE3

SPC interrupt/step code did not report Com-

 

 

 

 

mand Complete

 

 

 

 

 

 

 

 

0xE4

The SPC interrupt request could not be

 

 

 

 

cleared

 

 

 

 

 

 

 

 

0xE5

SPC did not generate an interrupt request

 

 

 

 

 

 

 

 

0xE6

SPC interrupt was not detected at the Interrupt

 

 

 

 

Request Controller

 

 

 

 

 

 

 

 

0xE7

The SPC interrupt was cleared while clearing

 

 

 

 

the Interrupt Request Controller.

 

 

 

 

 

 

 

 

0xE8

SPC interrupt/step code did not report Diag-

 

 

 

 

nostic Self-Test passed

 

 

 

 

 

 

 

 

0xE9

The SPC interrupt request could not be

 

 

 

 

cleared

 

 

 

 

 

 

 

 

0x10

At end of test, SPC did not generate an inter-

 

 

 

 

rupt request.

 

 

 

 

 

 

 

 

0x11

At end of test, SPC interrupt was not detected

 

 

 

 

at the Interrupt Request Controller.

 

 

 

 

 

 

 

 

0x12

At end of test, the SPC interrupt was cleared

 

 

 

 

while clearing the Interrupt Request Control-

 

 

 

 

ler.

 

 

 

 

 

 

 

 

0x13

At end of test, SPC interrupt/step code did not

 

 

 

 

report Command Complete.

 

 

 

 

 

 

 

 

0x14

At end of test, the SPC interrupt request could

 

 

 

 

not be cleared.

 

 

 

 

 

 

 

 

0xEF

SPC interrupt request or interrupt/step register

 

 

 

 

could not be cleared at the end of the test

 

 

 

 

 

0x12

0x01

SDDP-R20 buffer flush signal

0x01

after a write diag operation was initialized in

 

 

test, mode 14h

 

the spc chip, the SPC-status register did not

 

 

 

 

have one of the following:

 

 

 

 

SPC_data_trans_rdy, SPC_busy, or

 

 

 

 

SPC_data_reg_empty.

 

 

 

 

 

 

 

 

0x02

A non SUCCESS status was returned from

 

 

 

 

the function call rm_request_wrtbuffer.

 

 

 

 

 

F-38

CG00000-011503 REV. A

April 1997

Page 438
Image 438
Fujitsu M2488 manual Diagnostic Tests and Error Codes