April 1997 CG00000-011503 REV. A F-69 Table F-19. Routine 80 - Servo Diagnostic Error Codes
ROUTINE TEST TITLE ERROR
CODE DESCRIPTION
0x80 * Servo Diagnostic Tests 0xE0 Test initialization error, the controller could
not sense the presence of a DVL card. The
DTC card must be connected to a DVL card in
order to run this test.
0xE1 Test initialization error, a servo unload com-
mand failed while attempting to eject a car-
tridge.
0xE2 Servo reported error while attempting to
unload a cartridge during test initialization.
0x80 0x01 Servo Diag: Logic test 0x41 Dummy signal of the file reel tachometer is
wrong
0x42 GAP counter is wrong
0x43 RRC counter is wrong
0x44 Forward direction of the file reel tachometer is
wrong
0x45 Backward direction of the file reel tachometer
is wrong
0x46 Dummy signal of the machine reel tachometer
is wrong
0x47 Forward direction of the machine reel
tachometer is wrong
0x48 Backward direction of the machine reel
tachometer is wrong
0xE3 Servo command was not accepted; sense
information was built
0xE4 Servo command was accepted but failed to
complete within 60 seconds
0xE5 Servo error occurred that was not reported as
a diagnostic error.
0x80 0x02 Servo Diag: Photo sensors test 0x02 The tape path home sensor is off
0x03 The cartridge in sensor is on
0x04 The tape path “CT” sensor is off
0x05 The tape path “MR” sensor is on
0x06 The cartridge in sensor in on
0x07 The file protect sensor is off
0x08 The cleaning cartridge sensor is on