FAULT SYMPTOM CODES

M2488 PRODUCT GUIDE

 

 

Table D-2. Formatter Error Recovery (Continued)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BYTES

 

 

F.S.C. #

DESCRIPTION

 

E.R.P.A.

29-39

 

 

 

 

 

 

GROUP

 

 

 

 

 

 

 

 

 

9009

4 Meter Tones - 18 Track DID tone dropout

 

23/25

04

 

 

 

 

 

 

 

 

 

900A

4 Meter Tones - Too many total tone dropouts

 

23/25

04

 

 

 

 

 

 

 

 

 

900B

4 Meter Tones - Too many continuous tone dropouts

 

23/25

04

 

 

 

 

 

 

 

 

 

900C

4 Meter Tones - Continuous ERG tone not met

 

23/25

04

 

 

 

 

 

 

 

 

 

900D

4 Meter Tones - Continuous IBG tone not met

 

23/25

04

 

 

 

 

 

 

 

 

 

900E

4 Meter Tones - Continuous TM tone not met

 

23/25

04

 

 

 

 

 

 

 

 

 

900F

4 Meter Tones - Continuous 18 Track DID tone not met

 

23/25

04

 

 

 

 

 

 

 

 

 

9010

4 Meter Tones - Total not met on Wrap Mark

 

23/25

04

 

 

 

 

 

 

 

 

 

9011

4 Meter Tones - Continues not met on Wrap Mark

 

23/25

04

 

 

 

 

 

 

 

 

 

9012

4 Meter Tones - Continues not met on 36 Track DID

 

23/25

04

 

 

 

 

 

 

 

 

 

9013

4 Meter Tones - Total not met on 36 Track DID

 

23/25

04

 

 

 

 

 

 

 

 

 

9061

Too many total drops on Read DID

 

23

01

 

 

 

 

 

 

 

 

 

9062

Continuous not met on Read DID

 

23

01

 

 

 

 

 

 

 

 

 

9063

Continuous not met on Read TM

 

23

01

 

 

 

 

 

 

 

 

 

9064

DID too long on Read

 

23

01

 

 

 

 

 

 

 

 

 

9180

Hardware error on readback at end of IBG

 

25

04

 

 

 

 

 

 

 

 

 

9181

DBOB off between HBOB and DPRE

 

25

04

 

 

 

 

 

 

 

 

 

9182

DPRE time-out after PHOK on

 

25

04

 

 

 

 

 

 

 

 

 

9183

DBOB off before DPOST is detected

 

25

04

 

 

 

 

 

 

 

 

 

9184

RDEND on before DPOST is detected

 

25

04

 

 

 

 

 

 

 

 

 

9185

RDEND time-out after DPOST is detected

 

25

04

 

 

 

 

 

 

 

 

 

9188

Long IBG detected

 

25

04

 

 

 

 

 

 

 

 

 

918A

RECA dropped at DID write

 

28

04

 

 

 

 

 

 

 

 

 

918B

Can’t set RECA at DID write

 

28

04

 

 

 

 

 

 

 

 

 

918C

Dropout detected at IDS write

 

28

04

 

 

 

 

 

 

 

 

 

918D

Dropout detected at IBG after IDS write

 

25

04

 

 

 

 

 

 

 

 

 

918E

Misposition by servo, started too late into IBG

 

23

04

 

 

 

 

 

 

 

 

 

918F

Misposition by servo, started over previous block or mark

 

23

04

 

 

 

 

 

 

 

 

 

9190

Can’t detect regular DTM length

 

25

04

 

 

 

 

 

 

 

 

 

9191

Can’t detect regular length IBG after DTM

 

25

04

 

 

 

 

 

 

 

 

D-4

CG00000-011503 REV. A

April 1997

Page 384
Image 384
Fujitsu M2488 manual Table D-2. Formatter Error Recovery