DIAGNOSTIC TESTS AND ERROR CODES

DIAGNOSTIC TESTS AND ERROR CODES

 

M2488 PRODUCT GUIDE

Table F-15. Routine 13 - EDRC Error Detection Diagnostic Error Codes (Continued)

 

 

 

 

 

ROUTINE

TEST

TITLE

ERROR

DESCRIPTION

CODE

 

 

 

 

 

 

 

 

 

0x13

0x0A

Read Sync host_count-high /

0x01

Failed to receive data end-of-transfer signal in

 

 

compression error / sgd

 

SDDP hdxs register.

 

 

host_count-high errs

 

 

 

 

 

 

 

 

 

 

0x02

Incorrect SPC SCSI control signal status wait-

 

 

 

 

ing for REQ signal assertion.

 

 

 

 

 

 

 

 

0x03

Incorrect SPC SCSI control signal status wait-

 

 

 

 

ing for REQ signal deassertion.

 

 

 

 

 

 

 

 

0x04

Data transfer length error reported by SPC

 

 

 

 

 

 

 

 

0x05

SDDP failed to report expected data compres-

 

 

 

 

sion and sync host count error.

 

 

 

 

 

 

 

 

0x06

SDDP failed to report expected data compres-

 

 

 

 

sion host count error.

 

 

 

 

 

 

 

 

0x07

SDDP failed to report expected data compres-

 

 

 

 

sion host CRC error.

 

 

 

 

 

 

 

 

0x08

SDDP failed to report expected CRCA error.

 

 

 

 

 

0x13

0x0B

Read Sync host_count-low / com-

0x01

Failed to receive data end-of-transfer signal in

 

 

pression error / sgd host_count-

 

SDDP hdxs register.

 

 

low errs

 

 

 

 

 

 

 

 

 

 

0x02

Incorrect SPC SCSI control signal status wait-

 

 

 

 

ing for REQ signal assertion.

 

 

 

 

 

 

 

 

0x03

Incorrect SPC SCSI control signal status wait-

 

 

 

 

ing for REQ signal deassertion.

 

 

 

 

 

 

 

 

0x04

Data transfer length error reported by SPC

 

 

 

 

 

 

 

 

0x05

SDDP failed to report expected data compres-

 

 

 

 

sion and sync host count error.

 

 

 

 

 

 

 

 

0x06

SDDP failed to report expected data compres-

 

 

 

 

sion host count error.

 

 

 

 

 

 

 

 

0x07

SDDP failed to report expected data compres-

 

 

 

 

sion host CRC error.

 

 

 

 

 

 

 

 

0x08

SDDP failed to report expected CRCA error.

 

 

 

 

 

0x13

0x0C

Read Sync host_crc / compression

0x01

Failed to receive data end-of-transfer signal in

 

 

error / sgd host_crc errors

 

SDDP hdxs register.

 

 

 

 

 

 

 

 

0x02

Incorrect SPC SCSI control signal status wait-

 

 

 

 

ing for REQ signal assertion.

 

 

 

 

 

 

 

 

0x03

Incorrect SPC SCSI control signal status wait-

 

 

 

 

ing for REQ signal deassertion.

 

 

 

 

 

 

 

 

0x04

Data transfer length error reported by SPC

 

 

 

 

 

 

 

 

0x05

SDDP failed to report expected data compres-

 

 

 

 

sion and sync host CRC error.

 

 

 

 

 

F-48

CG00000-011503 REV. A

April 1997

Page 448
Image 448