DIAGNOSTIC TESTS AND ERROR CODES

DIAGNOSTIC TESTS AND ERROR CODES

 

M2488 PRODUCT GUIDE

Table F-9. Routine 7 - SCSI Protocol Controller Diagnostic Error Codes (Continued)

 

 

 

 

 

ROUTINE

TEST

TITLE

ERROR

DESCRIPTION

CODE

 

 

 

 

 

 

 

 

 

0x07

0x01

SPC CP Bus Bit test

0x01

SPC data bus bit test failed, data miscompare

 

 

 

 

in walking one’s test

 

 

 

 

 

0x07

0x02

SPC User Program Memory test

0x01

SPC data miscompare during incremental

 

 

 

 

data pattern test of User Program Memory

 

 

 

 

 

 

 

 

0x02

SPC data miscompare during address bus bit

 

 

 

 

test in SPC User Program Memory

 

 

 

 

 

 

 

 

0x03

SPC data miscompare during read of SPC

 

 

 

 

User Program Memory after all bits were

 

 

 

 

inverted

 

 

 

 

 

0x07

0x03

SPC MCS Buffer test

0x01

Incorrect SPC status detected after issuing a

 

 

 

 

diagnostic n-byte message command

 

 

 

 

 

 

 

 

0x02

Incorrect SCSI bus status during diagnostic

 

 

 

 

data transfer while expecting REQ assertion

 

 

 

 

 

 

 

 

0x03

Incorrect SCSI bus status during diagnostic

 

 

 

 

data transfer while expecting REQ de-asser-

 

 

 

 

tion

 

 

 

 

 

 

 

 

0x04

SPC reported an incorrect data transfer length

 

 

 

 

 

 

 

 

0x05

Data miscompare detected in SPC low MCS

 

 

 

 

buffer after diagnostic message transfer

 

 

 

 

 

 

 

 

0x06

Data miscompare error detected in SPC high

 

 

 

 

MCS buffer after diagnostic message transfer

 

 

 

 

 

0x07

0x04

SPC to Data Buffer DMA test

0x01

Incorrect SPC status detected after issuing a

 

 

 

 

diagnostic data transfer to buffer command

 

 

 

 

 

 

 

 

0x02

Bad SCSI bus status detected waiting for REQ

 

 

 

 

assertion during diagnostic data transfer

 

 

 

 

 

 

 

 

0x03

Bad SCSI bus status detected waiting for REQ

 

 

 

 

de-assertion during diagnostic data transfer

 

 

 

 

 

 

 

 

0x04

SPC reported an incorrect transfer length after

 

 

 

 

completion of a diagnostic data transfer com-

 

 

 

 

mand

 

 

 

 

 

 

 

 

0x05

Error reported by Record/Buffer manager in

 

 

 

 

attempting to setup SDDP for a DMA transfer

 

 

 

 

 

 

 

 

0x06

Unexpected status returned by Record/Buffer

 

 

 

 

manager after DMA transfer

 

 

 

 

 

 

 

 

0x07

Data miscompare detected in SPC MCS

 

 

 

 

buffer

 

 

 

 

 

 

 

 

0x08

Bad SCSI bus status detected waiting for REQ

 

 

 

 

assertion during diagnostic data transfer

 

 

 

 

 

F-20

CG00000-011503 REV. A

April 1997

Page 420
Image 420