M2488 PRODUCT GUIDE

 

DIAGNOSTIC TESTS AND ERROR CODES

 

Table F-8. Routine 6 - Data Buffer Diagnostic Error Codes (Continued)

 

 

 

 

 

ROUTINE

TEST

TITLE

ERROR

DESCRIPTION

CODE

 

 

 

 

 

 

 

 

 

 

0x06

0x04

Buffer RAM address bus bit test

0x01

 

Address bus bit miscompare, possible open

 

 

 

 

 

address bit(s)

 

 

 

 

 

 

 

 

 

0x02

 

Address bus bit miscompare, possible short/

 

 

 

 

 

tied address bit(s)

 

 

 

 

 

 

0x06

0x05

Buffer RAM 0xAA data pattern

0x01

 

Data miscompare error

 

 

test

 

 

 

 

 

 

 

 

 

0x06

0x06

Buffer RAM 0x55 data pattern

0x01

 

Data miscompare error

 

 

test

 

 

 

 

 

 

 

 

 

0x06

0x07

Buffer RAM walking one's test

0x01

 

Data miscompare error

 

 

 

 

 

 

0x06

0x08

Buffer RAM incremental pattern

0x01

 

Data miscompare error

 

 

test

 

 

 

 

 

 

 

 

 

DIAGNOSTIC TESTS AND ERROR CODES

Table F-9. Routine 7 - SCSI Protocol Controller Diagnostic Error Codes

ROUTINE

TEST

TITLE

ERROR

DESCRIPTION

CODE

 

 

 

 

 

 

 

 

 

0x07

*

SPC Routine Initialization

0xD0

SPC register initialization failed

 

 

 

 

 

 

 

 

0xE0

SPC did not generate an interrupt request

 

 

 

 

 

 

 

 

0xE1

SPC interrupt was not detected at the Interrupt

 

 

 

 

Request Controller

 

 

 

 

 

 

 

 

0xE2

The SPC interrupt was cleared while clearing

 

 

 

 

the Interrupt Request Controller.

 

 

 

 

 

 

 

 

0xE3

SPC interrupt/step code did not report Com-

 

 

 

 

mand Complete

 

 

 

 

 

 

 

 

0xE4

The SPC interrupt request could not be

 

 

 

 

cleared

 

 

 

 

 

 

 

 

0xE5

SPC did not generate an interrupt request

 

 

 

 

 

 

 

 

0xE6

SPC interrupt was not detected at the Interrupt

 

 

 

 

Request Controller

 

 

 

 

 

 

 

 

0xE7

The SPC interrupt was cleared while clearing

 

 

 

 

the Interrupt Request Controller.

 

 

 

 

 

 

 

 

0xE8

SPC interrupt/step code did not report Diag-

 

 

 

 

nostic Self-Test passed

 

 

 

 

 

 

 

 

0xE9

The SPC interrupt request could not be

 

 

 

 

cleared

 

 

 

 

 

 

 

 

0xEF

SPC interrupt request or interrupt/step register

 

 

 

 

could not be cleared at the end of the test

 

 

 

 

 

April 1997

CG00000-011503 REV. A

F-19

Page 419
Image 419