M2488 PRODUCT GUIDE FLOWCHART S
April 1997 CG00000-011503 REV. A I-7Figure I-9. MODE PAGES Flowchart
TAPE UNIT
P
MODE PAGES
START MED-CHGR
TEST
START
TEST
PAGE 00
PAGE 00/B 02
BYT 02: 01 *
TEST
TEST
TEST
PAGE 00/B 0F
BYT 0F: 00 *
TEST
TEST
START PG 00: WRT
TEST
WTROM: Y
TEST
START : N START
START
PAGE 10/B 02
BYT 02: 00 *
TEST
TEST
PAGE 10/B 0F
BYT 0F: 00 *
TEST
TEST
START PG 10: WRT
TEST
WTROM: Y
TEST
START : N START
START
PAGE 00 ST ART PAGE 01
TEST
START
TEST
START PAGE 10
TEST
PAGE 01/B 02
BYT 02: 08 *
TEST
TEST
PAGE 01/B 0B
BYT 0B: 00 *
TEST
TEST
START PG 01: WRT
TEST
WTROM: Y
TEST
START : N START
START
PAGE 00/B 02
BYT 02: 00 *
TEST
TEST
PAGE 00/B 0F
BYT 0F: 00 *
TEST
TEST
START PG 00: WRT
TEST
WTROM: Y
TEST
START : N START
START
For definitions of Tape Unit Mode Pages, refer to Chapter 5.
* To change MODE PAGE bytes:
1. Go to block identified with an asterisk.
2. The flashing hex digit moves to the right with UNLOAD, to the left with SHIFT and UNLOAD.
3. Increment digit with START, decrement with SHIFT and START.
4. After change is completed, move to PG XX: WRT and save by executing WTROM: Y.
START : Indicates other options not shown
Tape Unit MODE PAGE S Default Settin gs:
(Bytes not shown are default=00)
Page 00: Byte 04 = FE
Page 01: Byte 02 = 08
Byte 03 = 10
Byte 08 = 10
Page 10: Byte 04 = 80
Byte 05 = 40
Byte 07 = 32
Byte 08 = C4
Byte 0B = 06
Byte 0E = 01
For definitions of Media Changer
Mode Pages, refer to Chapter 6.
Media Changer MODE PAGES
Default Settings:
Page 00: Byte 02 = 01
All other Bytes = 00
(From Figure I-1)