M2488 PRODUCT GUIDE

MAINTENANCE AND SERVICING

8-7 MAINTENANCE TERMINAL

The maintenance terminal is attached to the rear of the M2488 via the 9-pin DIN connector. It has two functions, use as a terminal to run diagnostics using keyboard input and as a debug port for use with special tools that can be accessed by remote attach with a modem.

8-7.1 Maintenance Interface

A 9-pin (DB-9) maintenance interface (DTE device) is provided on the rear panel of the tape drive which is used for maintenance and diagnostic operation. Nearly all maintenance and all diagnostic capabilities are accessible through this interface. The maintenance interface connector is shown in Figure 8-3 and the pin assignments are indicated in Table 8-24.

5 4 3 2 1

9 8 7 6

Figure 8-3. Maintenance Connector (M2488)

Table 8-24. Maintenance Interface Connector Pin Assignments

 

M2488

 

 

 

PC

 

 

 

 

 

 

 

CONNECTOR

 

 

 

 

 

 

CONTACT

SIGNAL NAME

ABBREVIATION

DIRECTION

25-PIN

 

SIGNAL

NUMBER

 

 

 

 

 

 

 

 

 

 

 

 

 

1

DATA CARRIER DETECT

DCD

IN

2

 

TX

 

 

 

 

 

 

 

2

RECEIVE DATA

RX

IN

3

 

RX

 

 

 

 

 

 

 

3

TRANSMIT DATA

TX

OUT

6

 

DSR

 

 

 

 

 

 

 

4

DATA TERMINAL READY

DTR

OUT

7

 

GND

 

 

 

 

 

 

 

5

SIGNAL GROUND

GND

 

20

 

DTR

 

 

 

 

 

 

 

6

DATA SET READY

DSR

IN

5

 

CTS

 

 

 

 

 

 

 

7

REQUEST TO SEND

RTS

OUT

4

 

RTS

 

 

 

 

 

 

 

8

CLEAR TO SEND

CTS

IN

 

 

 

 

 

 

 

 

 

 

9

RING INDICATOR

RI

IN

 

 

 

 

 

 

 

 

 

 

April 1997

CG00000-011503 REV. A

8-33

Page 343
Image 343
Fujitsu M2488 manual Maintenance Terminal, Maintenance Interface, Signal Name Abbreviation Direction, Number