MTU DIAGNOSTIC SPECIFICATIONS M2488 PRODUCT GUIDE
H-6 CG00000-011503 REV. A April 1997
H-4.3.3 ACL TEST: Two diagnostic tests to check the autoloader
(Set the tests in detail using the given parameters.)
The tests can be set using the following parameters:
H-4.3.4 TESTMODE: Diagnostic test to measure operations
(This test has no parameter.)
0x00 - S:LD HM : Start loading from the loader home position.
0x01 - S:CTG IN : Start loading from the cartridge-in position.
0x02 - S:CAR DW :Start loading from the carrier-down position.
DIAG parameter 4: For WITH CTG only, select an unloading position from the following:
0x00 - E:TH END : Start unloading from the thread end.
0x01 - E:CAR DW : Start unloading from the carrier-down position.
0x02 - 1/6 F PT : Start unloading from the cartridge-in position.
execute count: Specify an execution count. Specify a command execution count from 1 to 99,999.
When 0 is set, the command execution continues with no stop.
1) ACL LDUL:Load and unload cartridges sequentially from the top posi-
tion of the magazine. ------- CMD CD : 0x90
2) MAG UPDW:Move the magazine between two position. ------- CMD CD : 0x91
DIAG parameter 3: For MAGAZINE UP/DOWN test, set the following:
0xXX- STRT Position : Magazine up-down start position
ACL type: 0x00 - 0x09 (10 slot type)
0x00 - 0x04 (5 slot type)
FACL type: 0x00 - 0x06
DIAG parameter 4: For MAGAZINE UP/DOWN test, set the following:
0xXX- END Position : Magazine up-down end position.
ACL type: 0x00 - 0x09 (10 slot type)
0x00 - 0x04 (5 slot type)
FACL type: 0x00 - 0x06
execution time: For ACL LOAD/UNLOAD test, set the frequency in use of cleaning cartridge. Cleaning
cartridge in cleaning cell is loaded every setting counter. (from 1 to 99,999) Only FACL.
If DIAG command code is set “0x90” and execution time is set “999”, cleaning cartridge
is loaded one time.
execute count: Specify an execution count. Specify a command execution count from 1 to 99,999.
When 0 is set, the command execution continues with no stop.
1) M1:LOAD:Measure the cartridge loading time ------- CMD CD : 0x41
2) M2:TPPFM:Measure the tape acceleration/deceleration time. ------- CMD CD : 0x42
3) M3:AC/PS: Measure the tape access/positioning time. ------- CMD CD : 0x43
4) M4:MODCH: Measure the mode change time. ------- CMD CD : 0x44
5) M5:LOCAT: Measure the tape locating time. ------- CMD CD : 0x45
6) M6:REWND: Measure the tape rewinding time. ------- CMD CD : 0x46
7) M7:D.S.E: Measure the DSE time. ------- CMD CD : 0x47
8) M8:UNLD: Measure the cartridge unloading time. ------- CMD CD : 0x48
9) M9:CLEAN: Measure the cleaning time. ------- CMD CD : 0x49