MTU DIAGNOSTIC SPECIFICATIONS

 

M2488 PRODUCT GUIDE

0x00

- S:LD HM

: Start loading from the loader home position.

0x01

- S:CTG IN

:

Start loading from the cartridge-in position.

0x02

- S:CAR DW

:

Start loading from the carrier-down position.

DIAG parameter 4: For WITH CTG only, select an unloading position from the following:

0x00

- E:TH END

:

Start unloading from the thread end.

0x01

- E:CAR DW

:

Start unloading from the carrier-down position.

0x02

- 1/6 F PT

:

Start unloading from the cartridge-in position.

execute count: Specify an execution count. Specify a command execution count from 1 to 99,999. When 0 is set, the command execution continues with no stop.

H-4.3.3 ACL TEST: Two diagnostic tests to check the autoloader

(Set the tests in detail using the given parameters.)

1)ACL LDUL: Load and unload cartridges sequentially from the top posi- ------- CMD CD : 0x90 tion of the magazine.

2) MAG UPDW: Move the magazine between two position.-------

CMD CD : 0x91

The tests can be set using the following parameters:

DIAG parameter 3: For MAGAZINE UP/DOWN test, set the following:

0xXX- STRT Position

: Magazine up-down start position

 

ACL type:

0x00

- 0x09

(10 slot type)

 

 

0x00

- 0x04

(5 slot type)

 

FACL type:

0x00

- 0x06

 

DIAG parameter 4: For MAGAZINE UP/DOWN test, set the following:

0xXX- END Position

: Magazine up-down end position.

 

ACL type:

0x00

- 0x09

(10 slot type)

 

 

0x00

- 0x04

(5 slot type)

 

FACL type:

0x00

- 0x06

 

execution time: For ACL LOAD/UNLOAD test, set the frequency in use of cleaning cartridge. Cleaning cartridge in cleaning cell is loaded every setting counter. (from 1 to 99,999) Only FACL. If DIAG command code is set “0x90” and execution time is set “999”, cleaning cartridge is loaded one time.

execute count: Specify an execution count. Specify a command execution count from 1 to 99,999. When 0 is set, the command execution continues with no stop.

H-4.3.4 TESTMODE: Diagnostic test to measure operations

(This test has no parameter.)

1)

M1:LOAD:

Measure the cartridge loading time-------

CMD CD : 0x41

2)

M2:TPPFM:

Measure the tape acceleration/deceleration time.-------

CMD CD : 0x42

3)

M3:AC/PS:

Measure the tape access/positioning time.-------

CMD CD : 0x43

4)

M4:MODCH:

Measure the mode change time.-------

CMD CD : 0x44

5)

M5:LOCAT:

Measure the tape locating time.-------

CMD CD : 0x45

6)

M6:REWND:

Measure the tape rewinding time.-------

CMD CD : 0x46

7)

M7:D.S.E:

Measure the DSE time.-------

CMD CD : 0x47

8)

M8:UNLD:

Measure the cartridge unloading time.-------

CMD CD : 0x48

9)

M9:CLEAN:

Measure the cleaning time.-------

CMD CD : 0x49

H-6

CG00000-011503 REV. A

April 1997

Page 488
Image 488
Fujitsu M2488 manual ACL Test Two diagnostic tests to check the autoloader, Testmode Diagnostic test to measure operations