M2488 PRODUCT GUIDE

MTU DIAGNOSTIC SPECIFICATIONS

H-4.4 COMBINATION : Running test by combining up to ten commands

1)

#:F-READ

Forward read run-------

CMD CD : 0x01

 

(Forward read):

It is same “FWD READ” test of READ/WRITE test.

 

2)

#:B-READ

Backward read run-------

CMD CD : 0x02

 

(Backward

It is same “BWD READ” test of READ/WRITE test.

 

 

read):

 

 

3)

#:WRITE

Write operation-------

CMD CD : 0x03

 

(Write):

It is same “WRITE” test of READ/WRITE test.

 

4)

#:D.S.E. (DSE):

DSE operation-------

CMD CD : 0x04

 

 

It is same “D.S.E.”test of READ/WRITE test.

 

5)

#:LOCATE

High-speed tape run to a specified sector-------

CMD CD : 0x05

 

(Locate):

It is same “LOCATE” test of READ/WRITE test.

 

6)

#:REWIND

High-speed tape run to the wrap-1 BOT position-------

CMD CD : 0x06

 

(Rewind):

It is same “WRAP1 BOT” test of READ/WRITE test.

 

7)

#:UNLOAD

Unloading-------

CMD CD : 0x07

 

(Unload):

 

 

8)

#:LOAD (Load): Loading next tape from a magazine. (only ACL/FACL) -------

CMD CD : 0x08

9)

#:EJECT

Ejection (only ACL/FACL)-------

CMD CD : 0x80

 

(Eject):

 

 

10)

TAPE PATH:

Tape run between the specified start position and end posi- -------

CMD CD : 0x0B

 

 

tion.

 

 

 

It is same “TAPE PATH” test of READ/WRITE test.

 

11)

#:REPEAT

Repetition of run-------

CMD CD : 0x0A

 

(Running

This diagnostic test repeats execution of diagnostic test

 

 

repeat):

from a specified test.

 

The tests can be set using the following parameters:

DIAG parameter 6: Specify a repeat start position.

execute count: Specify an execution count. Specify a command execution count from 1 to 99,999. (When 0 is set, not repeat)

For example:

After end of 5th group, command code is set following:

DIAG command code is set “0x0A” diag_parameter 6 is set “2” execute count is set “3”

This diagnostic test repeats execution of diagnostic test

3 times from group 2 to group 5.

12) #:END

End of run-------

CMD CD : 0x0C

(Running end):

This is end of diagnostic test.

or 0xFF

H-4.5 Error reset command------- CMD CD : 0x70 or 0xF0

If A error is reported by the MTU during diagnostic test, it is necessary to issue this command.

April 1997

CG00000-011503 REV. A

H-9

Page 491
Image 491