M2488 PRODUCT GUIDE D IAGNOSTIC TESTS AND ERROR CODES
April 1997 CG00000-011503 REV. A F-75
0x81 0x06 Rewind 0x01 Cartridge not installed or drive NOT READY
error. A tape cartridge must be loaded before
this test can be run.
0x02 Timeout waiting for Servo Command Com-
plete during rewind operation.
0x03 Timeout waiting for Formatter Action Com-
plete during rewind operation.
0x04 Record Manager or Servo error reported dur-
ing rewind operation.
0x81 0x07 Locate Block 0x01 Error while attempting to locate block.
0x81 0x08 Space Block 0x01 Error while attempting to space block.
0x81 0x09 Write Filemarks 0x01 Cartridge not installed or drive NOT READY
error. A tape cartridge must be loaded before
this test can be run.
0x02 Cartridge WRITE PROTECT error. The car-
tridge must not be write protected for this test.
0x03 Buffer space request not granted for data
transfer.
0x04 Logical EOT encountered before all filemarks
had been written.
0x05 Timeout during write filemarks.
0x06 Error reported at completion of write
filemarks.
0x81 0x0A Space File 0x01 Error while attempting to space file.
0x81 0x0B Display MFG Results - (No error codes specific to this test)
Table F-22. Routine 81 - Manufacturing Test Diagnostic Error Codes (Continued)
ROUTINE TEST TITLE ERROR
CODE DESCRIPTION
DIAGNOSTIC TESTS
AND ERROR CODES