DIAGNOSTIC TESTS AND ERROR CODES M2488 PRODUCT GUIDE
F-40 CG00000-011503 REV. A April 1997
0x12 0x02 SDDP-R20 testing 64k sgc-i-
mem, mode 14h 0x07 All the data expected to be transferred out of
the SPC data fifo was not transferred to the
SDDP.
0x08 host data transfer end of transfer was received
when not expected, check to see if flush is tied
high to some other signal.
0x09 host data transfer end of transfer was not
received when expected, check to see if flush
is tied low to some other signal.
0x0A Host data transfer error detected on the retry
mode of this test.
0x0B A byte for byte miscompare was detected on
the data bytes stored in the data_buffer.
0x12 0x03 SDDP-R20 testing 16k sgd-i-
mem, mode 04h 0x01 After start of read operation, SPC-status did
not have SPC-busy and data_ready, possible
sddp did not send data to spc.
0x02 Once read operation had started, slow micro-
code was able to pull data out of spc_data fifo
faster then sddp could put into data fifo. Pos-
sible that the data pipe is broken.
0x03 At end of read operation, the SPC-status
should be not busy, not data_ready, and
data_fifo empty.
0x04 All the data expected to be transferred from
the SPC data_fifo to the SPC receive_buffer
was not transferred.
0x05 A non SUCCESS status was returned from
the function call rm_host_rd_complt. A error
was detected in the SDDP_HI-hdxs register.
0x07 A byte for byte miscompare was detected on
the data bytes stored in the SPC receive
buffer.
0x12 0x04 SDDP-R20 testing sgd-de con-
trols, mode 00h 0x01 After start of read operation, SPC-status did
not have SPC-busy and data_ready, possible
sddp did not send data to spc.
0x02 Once read operation had started, slow micro-
code was able to pull data out of spc_data fifo
faster then sddp could put into data fifo. Pos-
sible that the data pipe is broken.
0x03 At end of read operation, the SPC-status
should be not busy, not data_ready, and
data_fifo empty.
Table F-14. Routine 12 - EDRC Address Bus Diagnostic Error Codes (Continued)
ROUTINE TEST TITLE ERROR
CODE DESCRIPTION
DIAGNOSTIC TESTS
AND ERROR CODES