M2488 PRODUCT GUIDE D IAGNOSTIC TESTS AND ERROR CODES
April 1997 CG00000-011503 REV. A F-7 Table F-3. Routine 1 - Control Store Diagnostic Error Codes
ROUTINE TEST TITLE ERROR
CODE DESCRIPTION
0x01 0x01 Control store data bus test 0x01 Data miscompare clearing control store
address 0
0x02 Data bus bit miscompare
0x01 0x02 Control store byte boundary test 0x01 Control store address 0 not set to
0xFFFFFFFF
0x02 Control store address 0x04 couldn't be set to 0
0x03 Read/verify of control store byte write failed
0x04 Read/verify of control store data word failed
0x01 0x03 Control store half word boundary
test 0x01 Data miscompare clearing control store
address 0
0x02 Control store address 0x04 couldn’t be set to
0xFFFFFFFF
0x03 Read/verify of control store half-word write
failed
0x04 Read/verify of control store data word failed
0x01 0x04 Control store address bus test 0x01 Read/verify of control store address bus bit
failed
0x01 0x05 Control store incrementing pattern
test 0x01 Read/verify of control store incrementing pat-
tern failed
0x01 0x06 Control store data pattern AA test 0x01 Control store data word miscompare
0x01 0x07 Control store data pattern 55 test 0x01 Control store data word miscompare
0x01 0x08 Control store walking FFs test 0x01 Control store data miscompare
DIAGNOSTIC TESTS
AND ERROR CODES