DIAGNOSTIC TESTS AND ERROR CODES

DIAGNOSTIC TESTS AND ERROR CODES

 

M2488 PRODUCT GUIDE

Table F-12. Routine 10 - EDRC Control Signals Diagnostic Error Codes (Continued)

 

 

 

 

 

ROUTINE

TEST

TITLE

ERROR

DESCRIPTION

CODE

 

 

 

 

 

 

 

 

 

0x10

0x08

Read EDRC-NC 3 bytes 00, mode

0x05

A non SUCCESS status was returned from

 

 

04h

 

the function call rm_host_rd_complt. A error

 

 

 

 

was detected in the SDDP_HI-hdxs register.

 

 

 

 

 

 

 

 

0x07

A byte for byte miscompare was detected on

 

 

 

 

the data bytes stored in the SPC receive

 

 

 

 

buffer.

 

 

 

 

 

0x10

0x09

Read EDRC 3 bytes 00, mode 00h

0x01

A host data path end of transfer was not

 

 

 

 

detected in the allotted time.

 

 

 

 

 

 

 

 

0x02

when transferring data from the SPC data_fifo

 

 

 

 

to the SPC receive_buffer, the SPC-ssig regis-

 

 

 

 

ter did not have the expected bits set:

 

 

 

 

SCSI_REQ, SCSI_BSY, xfer_phase.

 

 

 

 

 

 

 

 

0x03

when transferring data from the SPC data_fifo

 

 

 

 

to the SPC receive_buffer, the SPC-ssig regis-

 

 

 

 

ter did not have the expected bits set:

 

 

 

 

~SCSI_REQ, SCSI_ACK, SCSI_BSY,

 

 

 

 

xfer_phase.

 

 

 

 

 

 

 

 

0x04

All the data expected to be transferred from

 

 

 

 

the SPC data_fifo to the SPC receive_buffer

 

 

 

 

was not transferred.

 

 

 

 

 

 

 

 

0x05

A non SUCCESS status was returned from

 

 

 

 

the function call rm_host_rd_complt. A error

 

 

 

 

was detected in the SDDP_HI-hdxs register.

 

 

 

 

 

 

 

 

0x07

A byte for byte miscompare was detected on

 

 

 

 

the data bytes stored in the SPC receive

 

 

 

 

buffer.

 

 

 

 

 

0x10

0x0A

Write EDRC 3 bytes 00, mode

0x01

after a write diag operation was initialized in

 

 

10h

 

the spc chip, the SPC-status register did not

 

 

 

 

have one of the following:

 

 

 

 

SPC_data_trans_rdy, SPC_busy, or

 

 

 

 

SPC_data_reg_empty.

 

 

 

 

 

 

 

 

0x02

when transferring data from the SPC send

 

 

 

 

buffer to the SPC data fifo, the SPC-ssig regis-

 

 

 

 

ter did not have the expected bits set:

 

 

 

 

SCSI_REQ, SCSI_BSY, xfer_phase.

 

 

 

 

 

 

 

 

0x03

when transferring data from the SPC send

 

 

 

 

buffer to the SPC data fifo, the SPC-ssig regis-

 

 

 

 

ter did not have the expected bits set:

 

 

 

 

~SCSI_REQ, SCSI_ACK, SCSI_BSY,

 

 

 

 

xfer_phase.

 

 

 

 

 

 

 

 

0x04

A non SUCCESS status was returned from

 

 

 

 

the function call rm_request_wrtbuffer.

 

 

 

 

 

F-30

CG00000-011503 REV. A

April 1997

Page 430
Image 430
Fujitsu M2488 manual Diagnostic Tests and Error Codes