M2488 PRODUCT GUIDE

TAPE UNIT PARAMETERS

5-2.5 Common Device-Type Control Parameters

Table 5-10. Page 0Ah - Common Device-type Control Parameters

 

 

 

 

 

 

 

BITS

 

 

 

 

 

MODE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SENSE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BYTES

7

 

6

 

5

 

4

 

3

 

2

1

0

DEFAULT

 

 

 

 

 

VALUES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

PS *

 

Reserved

 

 

 

 

 

Page Code

 

 

8Ah

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

Additional Page Length

 

 

06h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

Reserved

 

 

 

 

RLEC

01h

3

 

Queue Algorithm Modifier

 

 

Reserved

QErr

DQue

01h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

EECA

 

 

 

 

Reserved

 

 

RAENP

UAAENP

EAENP

00h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

Reserved

 

 

 

 

 

00h

 

 

 

 

 

 

 

6-7

 

 

 

Ready AEN Holdoff Period (0-0FFFFh microsecond)

 

0000h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*The PS bit must be set to 0 on a MODE SELECT command. Note: Changeable fields in the page are shaded.

** NOTE **

The only field that may be modified in this page is the RLEC bit. On a

MODE SELECT command, all other fields must be zero. On a MODE

SENSE command, only the RLEC field is reported as changeable.

Table 5-11. Page 0Ah - Common Device-type Control Parameters Field Description

BYTE

BIT

VALUE

DESCRIPTION

 

 

 

 

2

1

1

When set to one, the Report Log Exception Condition (RLEC) bit indicates that the

 

 

 

target reports log overflow conditions.

 

 

0

When set to zero, this bit indicates that log overflow conditions are not reported.

 

 

 

The RLEC bit is reported as changeable on a MODE SENSE command, and the

 

 

 

default value is one.

 

 

 

 

3

0

1

When set to one, the Disable Queuing (DQUE) bit indicates that tagged queueing

 

 

 

shall be disabled.

 

 

 

The default value reported for this field on a MODE SENSE command is one and

 

 

 

not changeable.

 

 

 

 

3

1

0

When set to zero, the Queue Error Management bit indicates that remaining sus-

 

 

 

pended I/O process shall resume after the contingent allegiance condition or

 

 

 

extended contingent allegiance condition.

 

 

 

The default value reported for this field on a MODE SENSE command is zero and

 

 

 

not changeable.

 

 

 

 

3

4-7

0

The Queue Algorithm Modifier field specifies restrictions on the algorithm used for

 

 

 

reordering commands that are tagged with the SIMPLE QUEUE TAG message.

 

 

 

The default value reported for this field on a MODE SENSE command is zero and

 

 

 

not changeable.

 

 

 

 

April 1997

CG00000-011503 REV. A

5-9

Page 245
Image 245
Fujitsu M2488 manual Rlec, Eeca