M2488 PRODUCT GUIDE

 

 

 

 

 

 

 

TAPE UNIT SCSI COMMANDS

 

 

Table 4-40.

Log Sense Page 31h, Track Error Statistics (Continued)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BITS

 

 

 

 

 

DEFAULT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BYTES

7

6

 

5

4

 

3

 

2

1

0

VALUE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

175

 

 

 

 

Parameter Length

 

 

08h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

176-

MSB

Number of ECC correctable read/write errors detected on track 15

 

 

 

 

183

 

LSB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

184-

MSB

 

 

 

Parameter Code

 

 

 

 

9010h

 

 

185

 

 

 

 

 

 

 

LSB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

186

DU

DS=1

 

TSD=1

ETC=0

 

 

TMC=0

0

LP=0

E0h or 60h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

187

 

 

 

 

Parameter Length

 

 

08h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

188-

MSB

Number of ECC correctable read/write errors detected on track 16

 

 

 

 

195

 

LSB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

196-

MSB

 

 

 

Parameter Code

 

 

 

 

9011h

 

 

197

 

 

 

 

 

 

 

LSB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

198

DU

DS=1

 

TSD=1

ETC=0

 

 

TMC=0

0

LP=0

E0h or 60h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

199

 

 

 

 

Parameter Length

 

 

08h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

200-

MSB

Number of ECC correctable read/write errors detected on track 17

 

 

 

 

207

 

LSB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

208-

MSB

 

 

 

Parameter Code

 

 

 

 

9012h

 

 

209

 

 

 

 

 

 

 

LSB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

210

DU

DS=1

 

TSD=1

ETC=0

 

 

TMC=0

0

LP=0

E0h or 60h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

211

 

 

 

 

Parameter Length

 

 

08h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

212-

MSB

Number of ECC correctable read/write errors detected on track 18

 

 

 

 

219

 

LSB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

** NOTE **

The sum of ECC correctable errors by track may not be equal to the total number of Read Data checks recovered by ECC. These hard- ware indicators are transitory and reflect only the tracks correcting at the end of the read or read after write operation.