M2488 PRODUCT GUIDE TAPE UNIT SCSI COMMANDS
April 1997 CG00000-011503 REV. A 4-47
** NOTE **
The sum of ECC correctable errors by track may not be equal to the
total number of Read Data checks recovered by ECC. These hard-
ware indicators are transitory and reflect only the tracks correcting at
the end of the read or read after write op eration.
175 Parameter Length 08h
176-
183
MSB Number of ECC correctable read/write errors detected on track 15 LSB
184-
185
MSB Parameter Code 9010h
LSB
186 DU DS=1 TSD=1 ETC=0 TMC=0 0 LP=0 E0h or 60h
187 Parameter Length 08h
188-
195
MSB Number of ECC correctable read/write errors detected on track 16 LSB
196-
197
MSB Parameter Code 9011h
LSB
198 DU DS=1 TSD=1 ETC=0 TMC=0 0 LP=0 E0h or 60h
199 Parameter Length 08h
200-
207
MSB Number of ECC correctable read/write errors detected on track 17 LSB
208-
209
MSB Parameter Code 9012h
LSB
210 DU DS=1 TSD=1 ETC=0 TMC=0 0 LP=0 E0h or 60h
211 Parameter Length 08h
212-
219
MSB Number of ECC correctable read/write errors detected on track 18 LSB
Table 4-40. Log Sense Page 31h, Track Error Statistics (Continued)
BITS DEFAULT
VALUE
BYTES 7 6 5 4 3 2 1 0