M2488 PRODUCT GUIDE

 

DIAGNOSTIC TESTS AND ERROR CODES

 

Table F-14. Routine 12 - EDRC Address Bus Diagnostic Error Codes (Continued)

 

 

 

 

 

 

ROUTINE

 

TEST

TITLE

ERROR

DESCRIPTION

 

CODE

 

 

 

 

 

 

 

 

 

 

 

 

0x12

 

0x08

SDDP-R20 Read flush testing,

0x04

 

All the data expected to be transferred from

 

 

 

mode 00h

 

 

the SPC data_fifo to the SPC receive_buffer

 

 

 

 

 

 

was not transferred.

 

 

 

 

 

 

 

 

 

 

 

0x05

 

A non SUCCESS status was returned from

 

 

 

 

 

 

the function call rm_host_rd_complt. A error

 

 

 

 

 

 

was detected in the SDDP_HI-hdxs register.

 

 

 

 

 

 

 

 

 

 

 

0x06

 

Incorrect residual data count in SDDP.

 

 

 

 

 

 

 

DIAGNOSTIC TESTS AND ERROR CODES

April 1997

CG00000-011503 REV. A

F-43

Page 443
Image 443