TAPE UNIT SCSI COMMANDS

 

 

 

 

 

M2488 PRODUCT GUIDE

 

 

Table 4-40.

Log Sense Page 31h, Track Error Statistics (Continued)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BITS

 

 

 

 

 

DEFAULT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BYTES

7

6

 

5

4

 

3

 

2

1

0

VALUE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

103

 

 

 

 

Parameter Length

 

 

08h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

104-

MSB

Number of ECC correctable read/write errors detected on track 9

 

 

 

 

111

 

LSB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

112-

MSB

 

 

 

Parameter Code

 

 

 

 

900Ah

 

 

113

 

 

 

 

 

 

 

LSB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

114

DU

DS=1

 

TSD=1

ETC=0

 

 

TMC=0

0

LP=0

E0h or 60h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

115

 

 

 

 

Parameter Length

 

 

08h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

116-

MSB

Number of ECC correctable read/write errors detected on track 10

 

 

 

 

123

 

LSB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

124-

MSB

 

 

 

Parameter Code

 

 

 

 

900Bh

 

 

125

 

 

 

 

 

 

 

LSB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

126

DU

DS=1

 

TSD=1

ETC=0

 

 

TMC=0

0

LP=0

E0h or 60h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

127

 

 

 

 

Parameter Length

 

 

08h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

128-

MSB

Number of ECC correctable read/write errors detected on track 11

 

 

 

 

135

 

LSB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

136-

MSB

 

 

 

Parameter Code

 

 

 

 

900Ch

 

 

137

 

 

 

 

 

 

 

LSB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

138

DU

DS=1

 

TSD=1

ETC=0

 

 

TMC=0

0

LP=0

E0h or 60h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

139

 

 

 

 

Parameter Length

 

 

08h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

140-

MSB

Number of ECC correctable read/write errors detected on track 12

 

 

 

 

147

 

LSB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

148-

MSB

 

 

 

Parameter Code

 

 

 

 

900Dh

 

 

149

 

 

 

 

 

 

 

LSB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

150

DU

DS=1

 

TSD=1

ETC=0

 

 

TMC=0

0

LP=0

E0h or 60h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

151

 

 

 

 

Parameter Length

 

 

08h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

152-

MSB

Number of ECC correctable read/write errors detected on track 13

 

 

 

 

159

 

LSB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

160-

MSB

 

 

 

Parameter Code

 

 

 

 

900Eh

 

 

161

 

 

 

 

 

 

 

LSB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

162

DU

DS=1

 

TSD=1

ETC=0

 

 

TMC=0

0

LP=0

E0h or 60h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

163

 

 

 

 

Parameter Length

 

 

08h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

164-

MSB

Number of ECC correctable read/write errors detected on track 14

 

 

 

 

171

 

LSB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

172-

MSB

 

 

 

Parameter Code

 

 

 

 

900Fh

 

 

173

 

 

 

 

 

 

 

LSB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

174

DU

DS=1

 

TSD=1

ETC=0

 

 

TMC=0

0

LP=0

E0h or 60h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4-46

CG00000-011503 REV. A

April 1997

Page 128
Image 128
Fujitsu M2488 manual 136