M2488 PRODUCT GUIDE D IAGNOSTIC TESTS AND ERROR CODES
April 1997 CG00000-011503 REV. A F-67 Table F-18. Routine 51 - Incrementing Block Length Test Error Codes
ROUTINE TEST TITLE ERROR
CODE DESCRIPTION
0x51 * Incrementing block length tests 0xE0 DVL card connection was not detected by the
DTC.
0xE1 A working tape was not loaded, or the tape
drive was not READY when the test started.
0xE2 The tape drive is not READY.
0x51 0x01 Write incrementing blocks test 0xE3 The tape (or magazine) is FILE PRO-
TECTED.
0x01 Cartridge not installed or drive NOT READY
error. A tape cartridge must be loaded before
this test can be run.
0x02 Cartridge WRITE PROTECT error. The car-
tridge must not be write protected for this test.
0x03 Buffer space request not granted for data
transfer.
0x04 Data transfer timed out.
0x05 Fatal error detected during data transfer.
0x06 Bad status reported on data transfer complete.
0x07 Logical EOT encountered during data trans-
fer.
0x08 Buffer flush timeout. Write from data buffer
to tape was not completed in the allocated
time.
0x09 Write data in error reported at end of data
transfer.
0x51 0x02 Rewind test 0x01 Cartridge not installed or drive NOT READY
error. A tape cartridge must be loaded before
this test can be run.
0x02 Timeout waiting for Servo Command Com-
plete during rewind operation.
0x03 Timeout waiting for Formatter Action Com-
plete during rewind operation.
0x04 Record Manager or Servo error reported dur-
ing rewind operation.
0x51 0x03 Read incrementing blocks test 0x01 Cartridge not installed or drive NOT READY
error. A tape cartridge must be loaded before
this test can be run.
0x02 Error detected while requesting buffer space
for data transfer.
DIAGNOSTIC TESTS
AND ERROR CODES