M2488 PRODUCT GUIDE

INSTALLATION INSTRUCTIONS

Figure 1-28. FACL Rear

1-6.7.3 Connect the M2488 and the FACL

Refer to Figure 1-29 and Figure 1-30 during performance of this procedure.

STEP ACTION

1Insert the grounding plate at the front of the M2488 drive as shown in Figure 1-29.

2Connect the cable CNJ24 and CNJ28 to the M2488 connectors CNP24 and CNP28. Route the CNJ24 cable through the inside of the corner post on the M2488. See Figure 1-30.

3Align the positioning projections on the M2488 to the holes on the rear of the FACL. Attach the three Allen bolts through the inside of the FACL into the grounding plate and tighten.

4Replace the top covers on the FACL. Tighten four screws to hold the covers in place.

5Replace the top cover on the M2488. Tighten the four screws to hold the cover in place. See Figure 1-31.

April 1997

CG00000-011503 REV. A

1-35