TAPE UNIT SCSI COMMANDS M2488 PRODUCT GUIDE
4-24 CG00000-011503 REV. A April 19974-3.6.4 INQUIRY Sense Keys
One of the following sense keys may be returned if a CHECK CONDITION was indicated:
Table 4-23. Default Vendor and Product Identification Fields
LUN VENDOR ID CONTROLLER
PRODUCT ID LUN PRODUCT ID
MTU “FUJITSU” “M2488” (single-ended
SCSI interface) “M2488”
“M2488D” (differential
SCSI interface)
MC “FUJITSU” “M2488” (single-ended
SCSI interface) “M2488A11” (ACL Medium Changer)
“M2488A12” (FACL Medium Changer)
“M2488D” (differential
SCSI interface) “M2488A11” (ACL Medium Changer)
“M2488A12” (FACL Medium Changer)
Unknown or not
connected “FUJITSU” “M2488” (single-ended
SCSI interface) “ ”(i.e. all ASCII spaces)
“M2488D” (differential
SCSI interface)
SENSE KEY CONDITION DESCRIPTION
4h HARDWARE ERROR 1. SCSI interface error occurred due to hardware failure (e.g.
transfer of INQUIRY data failed due to hardware failure).
2. Inquiry data could not be read from NVRAM due to a hardware
error.
5h ILLEGAL REQUEST 1. Reserved bit was found set in the CDB of the INQUIRY com-
mand.
2. The EVPD bit in the INQUIRY CDB is zero, but the Page Code
field is not zero.
3. An unsupported VPD page was requested in the INQUIRY
CDB.
4. A VPD page was requested from a LUN device type that is
unknown or not connected.
5. Flag bit in the INQUIRY CDB was set and Link bit was not set.