DIAGNOSTIC TESTS AND ERROR CODES

DIAGNOSTIC TESTS AND ERROR CODES

 

M2488 PRODUCT GUIDE

Table F-6. Routine 4 - Read Signal Verification Processor Diagnostic Error Codes (Continued)

 

 

 

 

 

ROUTINE

TEST

TITLE

ERROR

DESCRIPTION

CODE

 

 

 

 

 

 

 

 

 

0x04

0x04

RSVP Counters test -4 frame

0x04

Register CECC data miscompare after clear-

 

 

 

 

ing Response Available

 

 

 

 

 

0x04

0x05

RSVP Counters test -8 frame

0x01

Carry counter error

 

 

 

 

 

 

 

 

0x02

Timeout waiting for Response Available after

 

 

 

 

setting CECC Order Available

 

 

 

 

 

 

 

 

0x03

RSVP Interrupts not set as expected

 

 

 

 

 

 

 

 

0x04

Register CECC data miscompare after clear-

 

 

 

 

ing Response Available

 

 

 

 

 

0x04

0x06

RSVP Counters test - 16 frame

0x01

Carry counter error

 

 

 

 

 

 

 

 

0x02

Timeout waiting for Response Available after

 

 

 

 

setting CECC Order Available

 

 

 

 

 

 

 

 

0x03

RSVP Interrupts not set as expected

 

 

 

 

 

 

 

 

0x04

Register CECC data miscompare after clear-

 

 

 

 

ing Response Available

 

 

 

 

 

0x04

0x07

RSVP Counters test - single byte

0x01

Timeout waiting for Response Available after

 

 

mode

 

setting CECC Order Available testing counter

 

 

 

 

2, low byte carry out

 

 

 

 

 

 

 

 

0x02

RSVP Interrupts not set as expected testing

 

 

 

 

counter 2, low byte carry out

 

 

 

 

 

 

 

 

0x03

Register CECC data miscompare after reset-

 

 

 

 

ting Response Available testing counter 2, low

 

 

 

 

byte carry out

 

 

 

 

 

 

 

 

0x04

Timeout waiting for Response Available after

 

 

 

 

setting CECC Order Available testing counter

 

 

 

 

1, low byte carry out

 

 

 

 

 

 

 

 

0x05

RSVP Interrupts not set as expected testing

 

 

 

 

counter 1, low byte carry out

 

 

 

 

 

 

 

 

0x06

Register CECC data miscompare after reset-

 

 

 

 

ting Response Available testing counter 1, low

 

 

 

 

byte carry out

 

 

 

 

 

 

 

 

0x07

Timeout waiting for Response Available after

 

 

 

 

setting CECC Order Available testing counter

 

 

 

 

0, low byte carry out

 

 

 

 

 

 

 

 

0x08

RSVP Interrupts not set as expected testing

 

 

 

 

counter 0, low byte carry out

 

 

 

 

 

 

 

 

0x09

Register CECC data miscompare after reset-

 

 

 

 

ting Response Available testing counter 0, low

 

 

 

 

byte carry out

 

 

 

 

 

F-16

CG00000-011503 REV. A

April 1997

Page 416