M2488 PRODUCT GUIDE

 

DIAGNOSTIC TESTS AND ERROR CODES

Table F-9. Routine 7 - SCSI Protocol Controller Diagnostic Error Codes (Continued)

 

 

 

 

 

ROUTINE

TEST

TITLE

ERROR

DESCRIPTION

CODE

 

 

 

 

 

 

 

 

 

 

0x07

0x04

SPC to Data Buffer DMA test

0x09

 

Incorrect SCSI bus status during diagnostic

 

 

 

 

 

data transfer while expecting REQ de-asser-

 

 

 

 

 

tion

 

 

 

 

 

 

 

 

 

0x0A

 

SPC reported an incorrect data transfer length

 

 

 

 

 

 

 

 

 

0x0B

 

Record/Buffer manager did not report suc-

 

 

 

 

 

cessful completion for the DMA transfer

 

 

 

 

 

 

 

 

 

0x0C

 

Data miscompare detected in SPC MSC

 

 

 

 

 

buffer after DMA data transfer completed

 

 

 

 

 

 

 

 

 

0x10

 

SPC did not generate an interrupt request

 

 

 

 

 

 

 

 

 

0x11

 

SPC interrupt was not detected at the Interrupt

 

 

 

 

 

Request Controller

 

 

 

 

 

 

 

 

 

0x12

 

The SPC interrupt was cleared while clearing

 

 

 

 

 

the Interrupt Request Controller.

 

 

 

 

 

 

 

 

 

0x13

 

An incorrect SPC interrupt/step code was

 

 

 

 

 

reported

 

 

 

 

 

 

 

 

 

0x14

 

The SPC interrupt request could not be

 

 

 

 

 

cleared

 

 

 

 

 

 

 

 

 

0x20

 

SPC did not generate an interrupt request

 

 

 

 

 

 

 

 

 

0x21

 

SPC interrupt was not detected at the Interrupt

 

 

 

 

 

Request Controller

 

 

 

 

 

 

 

 

 

0x22

 

The SPC interrupt was cleared while clearing

 

 

 

 

 

the Interrupt Request Controller.

 

 

 

 

 

 

 

 

 

0x23

 

SPC interrupt/step code did not report Com-

 

 

 

 

 

mand Complete

 

 

 

 

 

 

 

 

 

0x24

 

The SPC interrupt request could not be

 

 

 

 

 

cleared

 

 

 

 

 

 

0x07

0x05

SPC MPU bus parity test

0x01

 

SPC reported incorrect status

 

 

 

 

 

 

 

 

 

0x02

 

Bad SCSI bus status detected waiting for REQ

 

 

 

 

 

assertion during diagnostic data transfer

 

 

 

 

 

 

 

 

 

0x03

 

Incorrect SCSI bus status during diagnostic

 

 

 

 

 

data transfer while expecting REQ de-asser-

 

 

 

 

 

tion

 

 

 

 

 

 

 

 

 

0x04

 

SPC did not generate an interrupt request

 

 

 

 

 

 

 

 

 

0x05

 

SPC interrupt was not detected at the Interrupt

 

 

 

 

 

Request Controller

 

 

 

 

 

 

 

 

 

0x06

 

The SPC interrupt was cleared while clearing

 

 

 

 

 

the Interrupt Request Controller.

 

 

 

 

 

 

 

 

 

0x07

 

SPC interrupt/step code did not report MPU

 

 

 

 

 

Parity Error as expected

 

 

 

 

 

 

DIAGNOSTIC TESTS AND ERROR CODES

April 1997

CG00000-011503 REV. A

F-21

Page 421
Image 421
Fujitsu M2488 manual Diagnostic Tests and Error Codes