M2488 PRODUCT GUIDE

 

DIAGNOSTIC TESTS AND ERROR CODES

 

Table F-11. Routine 9 - PCC Timers Diagnostic Error Codes (Continued)

 

 

 

 

 

ROUTINE

TEST

TITLE

ERROR

DESCRIPTION

CODE

 

 

 

 

 

 

 

 

 

 

0x09

0x03

PCC Timers Timer 2 test

0x02

 

FMT counter 2 low count carry-out bit not set

 

 

 

 

 

 

 

 

 

0x03

 

Timer 2 running too FAST compared against

 

 

 

 

 

FMT counter 2.

 

 

 

 

 

 

 

 

 

0x04

 

Timer 2 running too SLOW compared against

 

 

 

 

 

FMT counter 2.

 

 

 

 

 

 

Table F-12. Routine 10 - EDRC Control Signals Diagnostic Error Codes

 

 

 

 

 

ROUTINE

TEST

TITLE

ERROR

DESCRIPTION

CODE

 

 

 

 

 

 

 

 

 

 

0x10

*

All R20 Control Check Diagnos-

0xD0

 

SPC register initialization failed

 

 

tics

 

 

 

 

 

 

 

 

 

 

 

 

0xE0

 

SPC did not generate an interrupt request

 

 

 

 

 

 

 

 

 

0xE1

 

SPC interrupt was not detected at the Interrupt

 

 

 

 

 

Request Controller

 

 

 

 

 

 

 

 

 

0xE2

 

The SPC interrupt was cleared while clearing

 

 

 

 

 

the Interrupt Request Controller.

 

 

 

 

 

 

 

 

 

0xE3

 

SPC interrupt/step code did not report Com-

 

 

 

 

 

mand Complete

 

 

 

 

 

 

 

 

 

0xE4

 

The SPC interrupt request could not be

 

 

 

 

 

cleared

 

 

 

 

 

 

 

 

 

0xE5

 

SPC did not generate an interrupt request

 

 

 

 

 

 

 

 

 

0xE6

 

SPC interrupt was not detected at the Interrupt

 

 

 

 

 

Request Controller

 

 

 

 

 

 

 

 

 

0xE7

 

The SPC interrupt was cleared while clearing

 

 

 

 

 

the Interrupt Request Controller.

 

 

 

 

 

 

 

 

 

0xE8

 

SPC interrupt/step code did not report Diag-

 

 

 

 

 

nostic Self-Test passed

 

 

 

 

 

 

 

 

 

0xE9

 

The SPC interrupt request could not be

 

 

 

 

 

cleared

 

 

 

 

 

 

 

 

 

0x10

 

At end of test, SPC did not generate an inter-

 

 

 

 

 

rupt request.

 

 

 

 

 

 

 

 

 

0x11

 

At end of test, SPC interrupt was not detected

 

 

 

 

 

at the Interrupt Request Controller.

 

 

 

 

 

 

 

 

 

0x12

 

At end of test, the SPC interrupt was cleared

 

 

 

 

 

while clearing the Interrupt Request Control-

 

 

 

 

 

ler.

 

 

 

 

 

 

DIAGNOSTIC TESTS AND ERROR CODES

April 1997

CG00000-011503 REV. A

F-25

Page 425
Image 425
Fujitsu M2488 manual Diagnostic Tests and Error Codes