M2488 PRODUCT GUIDE D IAGNOSTIC TESTS AND ERROR CODES
April 1997 CG00000-011503 REV. A F-11
0x03 0x02 CP Bus parity - SDDP 0x0A An unexpected Check 1 condition was
detected after setting a bit to force bad parity
on writes to the SDDP
0x0B A Check 1 condition was not detected after
reading a register in the SDDP with the SDDP
set to cause bad parity
0x0C An unexpected Check 1 condition was pend-
ing after an attempt to clear it was made
0x10 A CP bus parity error was not detected after
writing byte 0 of an SDDP register word with
force bad parity set
0x11 An unexpected Check 1 condition was pend-
ing after an attempt to clear it was made
0x12 A CP bus parity error was not detected after
writing byte 1 of an SDDP register word with
force bad parity set
0x13 An unexpected Check 1 condition was pend-
ing after an attempt to clear it was made
0x14 A CP bus parity error was not detected after
writing byte 2 of an SDDP register word with
force bad parity set
0x15 An unexpected Check 1 condition was pend-
ing after an attempt to clear it was made
0x16 A CP bus parity error was not detected after
writing byte 3 of an SDDP register word with
force bad parity set
0x17 An unexpected Check 1 condition was pend-
ing after an attempt to clear it was made
0x18 A data miscompare was detected during a
read verify of the SDDP register used to test
parity error detection
0x19 An unexpected Check 1 condition was
detected after completing a successful read
verify of an SDDP register
0x03 0x03 CP Bus parity - SPC 0x01 An expected CP Bus parity error was not
detected
0x02 An unexpected Check 1 condition was
detected after an attempt was made to clear it
0x03 An expected CP bus parity error was not
detected after attempting to force bad SPC
parity
Table F-5. Routine 3 - CP Bus Parity Diagnostic Error Codes (Continued)
ROUTINE TEST TITLE ERROR
CODE DESCRIPTION
DIAGNOSTIC TESTS