M2488 PRODUCT GUIDE

 

DIAGNOSTIC TESTS AND ERROR CODES

 

Table F-5. Routine 3 - CP Bus Parity Diagnostic Error Codes (Continued)

 

 

 

 

 

ROUTINE

TEST

TITLE

ERROR

DESCRIPTION

CODE

 

 

 

 

 

 

 

 

 

 

0x03

0x02

CP Bus parity - SDDP

0x0A

 

An unexpected Check 1 condition was

 

 

 

 

 

detected after setting a bit to force bad parity

 

 

 

 

 

on writes to the SDDP

 

 

 

 

 

 

 

 

 

0x0B

 

A Check 1 condition was not detected after

 

 

 

 

 

reading a register in the SDDP with the SDDP

 

 

 

 

 

set to cause bad parity

 

 

 

 

 

 

 

 

 

0x0C

 

An unexpected Check 1 condition was pend-

 

 

 

 

 

ing after an attempt to clear it was made

 

 

 

 

 

 

 

 

 

0x10

 

A CP bus parity error was not detected after

 

 

 

 

 

writing byte 0 of an SDDP register word with

 

 

 

 

 

force bad parity set

 

 

 

 

 

 

 

 

 

0x11

 

An unexpected Check 1 condition was pend-

 

 

 

 

 

ing after an attempt to clear it was made

 

 

 

 

 

 

 

 

 

0x12

 

A CP bus parity error was not detected after

 

 

 

 

 

writing byte 1 of an SDDP register word with

 

 

 

 

 

force bad parity set

 

 

 

 

 

 

 

 

 

0x13

 

An unexpected Check 1 condition was pend-

 

 

 

 

 

ing after an attempt to clear it was made

 

 

 

 

 

 

 

 

 

0x14

 

A CP bus parity error was not detected after

 

 

 

 

 

writing byte 2 of an SDDP register word with

 

 

 

 

 

force bad parity set

 

 

 

 

 

 

 

 

 

0x15

 

An unexpected Check 1 condition was pend-

 

 

 

 

 

ing after an attempt to clear it was made

 

 

 

 

 

 

 

 

 

0x16

 

A CP bus parity error was not detected after

 

 

 

 

 

writing byte 3 of an SDDP register word with

 

 

 

 

 

force bad parity set

 

 

 

 

 

 

 

 

 

0x17

 

An unexpected Check 1 condition was pend-

 

 

 

 

 

ing after an attempt to clear it was made

 

 

 

 

 

 

 

 

 

0x18

 

A data miscompare was detected during a

 

 

 

 

 

read verify of the SDDP register used to test

 

 

 

 

 

parity error detection

 

 

 

 

 

 

 

 

 

0x19

 

An unexpected Check 1 condition was

 

 

 

 

 

detected after completing a successful read

 

 

 

 

 

verify of an SDDP register

 

 

 

 

 

 

0x03

0x03

CP Bus parity - SPC

0x01

 

An expected CP Bus parity error was not

 

 

 

 

 

detected

 

 

 

 

 

 

 

 

 

0x02

 

An unexpected Check 1 condition was

 

 

 

 

 

detected after an attempt was made to clear it

 

 

 

 

 

 

 

 

 

0x03

 

An expected CP bus parity error was not

 

 

 

 

 

detected after attempting to force bad SPC

 

 

 

 

 

parity

 

 

 

 

 

 

DIAGNOSTIC TESTS AND ERROR CODES

April 1997

CG00000-011503 REV. A

F-11

Page 411