DIAGNOSTIC TESTS AND ERROR CODES M2488 PRODUCT GUIDE
F-24 CG00000-011503 REV. A April 1997
0x08 0x03 Formatter Counter 2 test 0x02 A data miscompare occurred walking a one
through the Formatter Counter 2 high byte
count register
0x03 A data miscompare occurred walking a one
through the Formatter Counter 2 low byte
count register
0x04 Test Jump Carry Out bit for the high byte
count of Formatter Counter 2 was set prema-
turely before counter was started
0x05 An unexpected value was read in the count
enable register for Formatter Counter 2 after
the high byte counter finished running
0x06 The high byte count for Formatter Counter 2
did not contain the expected value after the
counter finished running
0x07 Test Jump Carry Out bit for the high byte
count of Formatter Counter 2 was not set as
expected after the counter finished running
0x08 Test Jump Carry Out bit for the low byte
count of Formatter Counter 2 was set prema-
turely before counter was started
0x09 An unexpected value was read in the count
enable register for Formatter Counter 2 after
the low byte counter finished running
0x0A The low byte count for Formatter Counter 2
did not contain the expected value after the
counter finished running
0x0B Test Jump Carry Out bit for the low byte
count of Formatter Counter 2 was not set as
expected after the counter finished running
Table F-11. Routine 9 - PCC Timers Diagnostic Error Codes
ROUTINE TEST TITLE ERROR
CODE DESCRIPTION
0x09 0x01 PCC Timers Timer 0 test 0x01 10ms Timer (timer 0) interrupt was not
detected
0x09 0x02 PCC Timers Timer 1 test 0x01 Deadman Timer (timer 1) interrupt was not
detected
0x09 0x03 PCC Timers Timer 2 test 0x01 Real Time Clock (timer 2) not incrementing
Table F-10. Routine 8 - Formatter Counters Diagnostic Error Codes (Continued)
ROUTINE TEST TITLE ERROR
CODE DESCRIPTION
DIAGNOSTIC TESTS
AND ERROR CODES