DIAGNOSTIC TESTS AND ERROR CODES

DIAGNOSTIC TESTS AND ERROR CODES

 

M2488 PRODUCT GUIDE

 

Table F-10. Routine 8 - Formatter Counters Diagnostic Error Codes (Continued)

 

 

 

 

 

 

ROUTINE

 

TEST

TITLE

ERROR

DESCRIPTION

 

CODE

 

 

 

 

 

 

 

 

 

 

 

0x08

 

0x03

Formatter Counter 2 test

0x02

A data miscompare occurred walking a one

 

 

 

 

 

through the Formatter Counter 2 high byte

 

 

 

 

 

count register

 

 

 

 

 

 

 

 

 

 

0x03

A data miscompare occurred walking a one

 

 

 

 

 

through the Formatter Counter 2 low byte

 

 

 

 

 

count register

 

 

 

 

 

 

 

 

 

 

0x04

Test Jump Carry Out bit for the high byte

 

 

 

 

 

count of Formatter Counter 2 was set prema-

 

 

 

 

 

turely before counter was started

 

 

 

 

 

 

 

 

 

 

0x05

An unexpected value was read in the count

 

 

 

 

 

enable register for Formatter Counter 2 after

 

 

 

 

 

the high byte counter finished running

 

 

 

 

 

 

 

 

 

 

0x06

The high byte count for Formatter Counter 2

 

 

 

 

 

did not contain the expected value after the

 

 

 

 

 

counter finished running

 

 

 

 

 

 

 

 

 

 

0x07

Test Jump Carry Out bit for the high byte

 

 

 

 

 

count of Formatter Counter 2 was not set as

 

 

 

 

 

expected after the counter finished running

 

 

 

 

 

 

 

 

 

 

0x08

Test Jump Carry Out bit for the low byte

 

 

 

 

 

count of Formatter Counter 2 was set prema-

 

 

 

 

 

turely before counter was started

 

 

 

 

 

 

 

 

 

 

0x09

An unexpected value was read in the count

 

 

 

 

 

enable register for Formatter Counter 2 after

 

 

 

 

 

the low byte counter finished running

 

 

 

 

 

 

 

 

 

 

0x0A

The low byte count for Formatter Counter 2

 

 

 

 

 

did not contain the expected value after the

 

 

 

 

 

counter finished running

 

 

 

 

 

 

 

 

 

 

0x0B

Test Jump Carry Out bit for the low byte

 

 

 

 

 

count of Formatter Counter 2 was not set as

 

 

 

 

 

expected after the counter finished running

 

 

 

 

 

 

Table F-11. Routine 9 - PCC Timers Diagnostic Error Codes

ROUTINE

TEST

TITLE

ERROR

DESCRIPTION

CODE

 

 

 

 

 

 

 

 

 

0x09

0x01

PCC Timers Timer 0 test

0x01

10ms Timer (timer 0) interrupt was not

 

 

 

 

detected

 

 

 

 

 

0x09

0x02

PCC Timers Timer 1 test

0x01

Deadman Timer (timer 1) interrupt was not

 

 

 

 

detected

 

 

 

 

 

0x09

0x03

PCC Timers Timer 2 test

0x01

Real Time Clock (timer 2) not incrementing

 

 

 

 

 

F-24

CG00000-011503 REV. A

April 1997

Page 424
Image 424
Fujitsu M2488 manual Table F-11. Routine 9 PCC Timers Diagnostic Error Codes