DIAGNOSTIC TESTS AND ERROR CODES

M2488 PRODUCT GUIDE

DIAGNOSTIC TESTS AND ERROR CODES

Table F-15. Routine 13 - EDRC Error Detection Diagnostic Error Codes

ROUTINE

TEST

TITLE

ERROR

DESCRIPTION

CODE

 

 

 

 

 

 

 

 

 

0x13

*

All R20 Error Check Diagnostics

0xD0

SPC register initialization failed

 

 

 

 

 

 

 

 

0xE0

SPC did not generate an interrupt request

 

 

 

 

 

 

 

 

0xE1

SPC interrupt was not detected at the Interrupt

 

 

 

 

Request Controller

 

 

 

 

 

 

 

 

0xE2

The SPC interrupt was cleared while clearing

 

 

 

 

the Interrupt Request Controller.

 

 

 

 

 

 

 

 

0xE3

SPC interrupt/step code did not report Com-

 

 

 

 

mand Complete

 

 

 

 

 

 

 

 

0xE4

The SPC interrupt request could not be

 

 

 

 

cleared

 

 

 

 

 

 

 

 

0xE5

SPC did not generate an interrupt request

 

 

 

 

 

 

 

 

0xE6

SPC interrupt was not detected at the Interrupt

 

 

 

 

Request Controller

 

 

 

 

 

 

 

 

0xE7

The SPC interrupt was cleared while clearing

 

 

 

 

the Interrupt Request Controller.

 

 

 

 

 

 

 

 

0xE8

SPC interrupt/step code did not report Diag-

 

 

 

 

nostic Self-Test passed

 

 

 

 

 

 

 

 

0xE9

The SPC interrupt request could not be

 

 

 

 

cleared

 

 

 

 

 

 

 

 

0x10

At end of test, SPC did not generate an inter-

 

 

 

 

rupt request.

 

 

 

 

 

 

 

 

0x11

At end of test, SPC interrupt was not detected

 

 

 

 

at the Interrupt Request Controller.

 

 

 

 

 

 

 

 

0x12

At end of test, the SPC interrupt was cleared

 

 

 

 

while clearing the Interrupt Request Control-

 

 

 

 

ler.

 

 

 

 

 

 

 

 

0x13

At end of test, SPC interrupt/step code did not

 

 

 

 

report Command Complete.

 

 

 

 

 

 

 

 

0x14

At end of test, the SPC interrupt request could

 

 

 

 

not be cleared.

 

 

 

 

 

 

 

 

0xEF

SPC interrupt request or interrupt/step register

 

 

 

 

could not be cleared at the end of the test

 

 

 

 

 

0x13

0x01

Write Hi_data parity error check

0xA0

SPC did not generate an interrupt request

 

 

 

 

 

 

 

 

0xA1

SPC interrupt was not detected at the Interrupt

 

 

 

 

Request Controller

 

 

 

 

 

 

 

 

0xA2

The SPC interrupt was cleared while clearing

 

 

 

 

the Interrupt Request Controller.

 

 

 

 

 

F-44

CG00000-011503 REV. A

April 1997

Page 444
Image 444
Fujitsu M2488 manual Diagnostic Tests and Error Codes