ASC/ASCQ

 

M2488 PRODUCT GUIDE

 

 

Table B-1. ASC and ASCQ Description (by Sense Key) (Continued)

 

 

 

 

 

 

SENSE

ASC/ASCQ

DESCRIPTION

ADVISED

KEY

ACTION

 

 

 

 

 

 

 

 

4

44

00

Hardware error

1

 

 

 

 

 

5

1A

00

Parameter list length error

1

 

 

 

 

 

 

20

00

Invalid command operation code

1

 

 

 

 

 

 

21

01

Invalid medium changer element address

1

 

 

 

 

 

 

24

00

Invalid field in CDB

1

 

 

 

 

 

 

25

00

Logical unit not supported

1

 

 

 

 

 

 

26

00

Invalid field in parameter list

1

 

 

 

 

 

 

30

02

Incompatible format

8

 

 

 

 

 

 

3B

0D

Destination medium changer element full

1

 

 

 

 

 

 

3B

0E

No cartridge or magazine at specified medium changer source element position

1

 

 

 

 

 

 

3B

8F

First destination medium changer element empty

1

 

 

 

 

 

 

3B

90

Second destination medium changer element full

1

 

 

 

 

 

 

3B

91

Second destination medium changer element empty

1

 

 

 

 

 

 

3B

92

Medium changer transport element full

1

 

 

 

 

 

 

3B

93

Medium changer element is not accessible

1

 

 

 

 

 

 

3B

94

Drive is full, operation cannot be performed

1

 

 

 

 

 

 

3D

00

Invalid bits in IDENTIFY message

1

 

 

 

 

 

6

28

00

Not ready to ready transition (Priority 2)

7

 

 

 

 

 

 

29

00

Power on, reset, or BUS DEVICE RESET occurred (Priority 1)

7

 

 

 

 

 

 

2A

01

Mode parameters changed (Priority 5)

7

 

 

 

 

 

 

33

00

Tape length error (Priority 3)

7

 

 

 

 

 

 

3F

01

Microcode has been changed (Priority 4)

7

 

 

 

 

 

7

27

00

Write protected

5,4

 

 

 

 

 

8

00

05

Tape void

1

 

 

 

 

 

 

30

01

Cannot read medium - unknown format

1

 

 

 

 

 

B

43

00

Message reject error

1

 

 

 

 

 

 

44

00

Internal target failure

4

 

 

 

 

 

 

45

00

No initiator response to reselection

1

 

 

 

 

 

 

47

00

SCSI parity error

1

 

 

 

 

 

 

48

00

Active SCSI command aborted due to an Initiator detected error message being re-

1

 

 

 

ceived

 

 

 

 

 

 

 

49

00

Invalid message error

1

 

 

 

 

 

 

4B

00

SPC transfer offset error or transfer period error

4

 

 

 

 

 

 

4E

00

Overlapped commands attempted

1

 

 

 

 

 

D

00

02

End-of-Medium detected

1

 

 

 

 

 

Table B-2. Action Advised Codes

ADVISED

ACTION CODE

DESCRIPTION

1

Treat the error as a permanent error.

2

Execute Dynamic Device Reconfiguration (DDR).

3

Continue processing.

B-2

CG00000-011503 REV. A

April 1997

Page 376
Image 376
Fujitsu manual ASC/ASCQ M2488 Product Guide, Table B-2. Action Advised Codes, ASC/ASCQ Description Advised KEY Action