M2488 PRODUCT GUIDE

 

DIAGNOSTIC TESTS AND ERROR CODES

 

Table F-5. Routine 3 - CP Bus Parity Diagnostic Error Codes (Continued)

 

 

 

 

 

ROUTINE

TEST

TITLE

ERROR

DESCRIPTION

CODE

 

 

 

 

 

 

 

 

 

 

0x03

0x03

CP Bus parity - SPC

0x43

 

The SPC interrupt/step code did not report a

 

 

 

 

 

Register Parity error as expected after chang-

 

 

 

 

 

ing the SPC parity from odd to even

 

 

 

 

 

 

 

 

 

0x44

 

The SPC interrupt request could not be

 

 

 

 

 

cleared

 

 

 

 

 

 

 

 

 

0x50

 

An SPC interrupt request was not generated

 

 

 

 

 

by the SPC during diagnostic test

 

 

 

 

 

 

 

 

 

0x51

 

An expected SPC interrupt was not detected

 

 

 

 

 

in the Interrupt Request Controller (IRC)

 

 

 

 

 

 

 

 

 

0x52

 

The SPC interrupt was inadvertently cleared

 

 

 

 

 

when the Interrupt Request Controller was

 

 

 

 

 

cleared

 

 

 

 

 

 

 

 

 

0x53

 

The SPC interrupt/step code did not report a

 

 

 

 

 

Register Parity error as expected after chang-

 

 

 

 

 

ing the SPC parity from odd to even

 

 

 

 

 

 

 

 

 

0x54

 

The SPC interrupt request could not be

 

 

 

 

 

cleared

 

 

 

 

 

 

 

 

 

0x60

 

An expected SPC interrupt request was not

 

 

 

 

 

generated by the SPC

 

 

 

 

 

 

 

 

 

0x61

 

An expected SPC interrupt was not detected

 

 

 

 

 

in the Interrupt Request Controller (IRC)

 

 

 

 

 

 

 

 

 

0x62

 

The SPC interrupt was inadvertently cleared

 

 

 

 

 

when the Interrupt Request Controller was

 

 

 

 

 

cleared

 

 

 

 

 

 

 

 

 

0x63

 

The SPC interrupt/step code did not report a

 

 

 

 

 

Command Complete as expected

 

 

 

 

 

 

 

 

 

0x64

 

The SPC interrupt request could not be

 

 

 

 

 

cleared

 

 

 

 

 

 

 

 

 

0x80

 

An SPC interrupt request was not generated

 

 

 

 

 

by the SPC during SPC setup restoration

 

 

 

 

 

 

 

 

 

0x81

 

An expected SPC interrupt was not detected

 

 

 

 

 

in the Interrupt Request Controller (IRC)

 

 

 

 

 

 

 

 

 

0x82

 

The SPC interrupt was inadvertently cleared

 

 

 

 

 

when the Interrupt Request Controller was

 

 

 

 

 

cleared

 

 

 

 

 

 

 

 

 

0x83

 

The SPC interrupt/step code did not report a

 

 

 

 

 

Command Complete as expected after restor-

 

 

 

 

 

ing SPC setup

 

 

 

 

 

 

 

 

 

0x84

 

The SPC interrupt request could not be

 

 

 

 

 

cleared

 

 

 

 

 

 

DIAGNOSTIC TESTS AND ERROR CODES

April 1997

CG00000-011503 REV. A

F-13

Page 413
Image 413