0x03 0x03 CP Bus parity - SPC 0x43 The SPC interrupt/step code did not report a
Register Parity error as expected after chang-
ing the SPC parity from odd to even
0x44 The SPC interrupt request could not be
cleared
0x50 An SPC interrupt request was not generated
by the SPC during diagnostic test
0x51 An expected SPC interrupt was not detected
in the Interrupt Request Controller (IRC)
0x52 The SPC interrupt was inadvertently cleared
when the Interrupt Request Controller was
cleared
0x53 The SPC interrupt/step code did not report a
Register Parity error as expected after chang-
ing the SPC parity from odd to even
0x54 The SPC interrupt request could not be
cleared
0x60 An expected SPC interrupt request was not
generated by the SPC
0x61 An expected SPC interrupt was not detected
in the Interrupt Request Controller (IRC)
0x62 The SPC interrupt was inadvertently cleared
when the Interrupt Request Controller was
cleared
0x63 The SPC interrupt/step code did not report a
Command Complete as expected
0x64 The SPC interrupt request could not be
cleared
0x80 An SPC interrupt request was not generated
by the SPC during SPC setup restoration
0x81 An expected SPC interrupt was not detected
in the Interrupt Request Controller (IRC)
0x82 The SPC interrupt was inadvertently cleared
when the Interrupt Request Controller was
cleared
0x83 The SPC interrupt/step code did not report a
Command Complete as expected after restor-
ing SPC setup
0x84 The SPC interrupt request could not be
cleared
Table F-5. Routine 3 - CP Bus Parity Diagnostic Error Codes (Continued)
ROUTINE TEST TITLE ERROR
CODE DESCRIPTION
DIAGNOSTIC TESTS