M2488 PRODUCT GUIDE

TAPE UNIT SCSI COMMANDS

Description of Page Code 81h

This page allows user selection of Manufacturing Online Diagnostic Routines and control over the number of times each routine is to be executed.

Table 4-120. Page 81h - Manufacturing Online Diagnostic Test Page

 

 

 

 

 

 

BITS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BYTES

7

6

5

 

4

 

3

 

2

1

0

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

Page code (81h)

 

 

 

 

 

 

 

 

 

1

 

 

Reserved (All bits are set to zero)

 

 

 

 

 

 

 

 

 

 

 

2-3

 

 

 

 

Page Length (001Eh)

 

 

 

 

 

 

 

 

 

4

 

 

Manufacturing Routine number

 

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

Execute Count

 

 

 

 

 

 

 

 

 

 

 

6

 

 

 

EDRC Compression Mode

 

 

 

 

 

 

 

 

 

 

 

 

7

 

 

 

 

Block Delay (ms)

 

 

 

 

 

 

 

 

 

 

 

 

8

 

 

 

 

Block Length (KB)

 

 

 

 

 

 

 

 

 

 

 

 

9-11

 

 

 

 

Block Count

 

 

 

 

 

 

 

 

 

 

 

 

12-13

 

 

 

 

Block Data Pattern

 

 

 

 

 

 

 

 

 

 

 

14-15

 

 

 

Data Pattern Increment

 

 

 

 

 

 

 

 

 

 

 

 

16-19

 

 

 

 

Block Number

 

 

 

 

 

 

 

 

 

 

 

 

20-23

 

 

 

 

Space Count

 

 

 

 

 

 

 

 

 

 

 

24-27

 

 

 

Write Filemark Count

 

 

 

 

 

 

 

 

 

28-33

 

 

Reserved (All bits are set to zero)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Description of fields in Page Code 81h

Table 4-121. Page Code 81h Field Description

BYTE

BIT

VALUE

DESCRIPTION

 

 

 

 

0

0-7

81h

Page Code for Manufacturing Online Diagnostics.

 

 

 

 

4

0-7

 

Manufacturing Routine number (refer to Chapter 8 for a list of Manufacturing rou-

 

 

 

tines).

 

 

 

 

5

0-7

 

Execute Count. The number of times to repeat the Manufacturing Online Diagnostic

 

 

 

Routine. A value of 0 indicates that the diagnostic will repeat until one of the follow-

 

 

 

ing conditions is met: a SCSI BUS RESET is issued, the initiator ABORTS this com-

 

 

 

mand, or a failure is detected during the execution of the Manufacturing Online

 

 

 

Diagnostic.

 

 

 

 

April 1997

CG00000-011503 REV. A

4-129

Page 211
Image 211
Fujitsu M2488 manual Description of Page Code 81h, Page 81h Manufacturing Online Diagnostic Test