TAPE UNIT SCSI COMMANDS

M2488 PRODUCT GUIDE

4-3.18.3 READ REVERSE Sense Keys

One of the following sense keys may be returned if a CHECK CONDITION was indicated:

SENSE KEY

CONDITION

 

DESCRIPTION

 

 

 

0h

NO SENSE

1. Filemark encountered.

 

 

2.

BOT encountered.

1h

RECOVERED ERROR

1. Recovery was performed when writing buffered data before the

 

 

 

READ REVERSE command was executed.

 

 

2.

Recovery was performed when reading data from tape.

3h

MEDIUM ERROR

1. Write of buffered data failed due to a defective tape. (Synchro-

 

 

 

nize before READ REVERSE attempted.)

 

 

2.

Error occurred when attempting to space backward over block

 

 

 

to be read.

 

 

3.

An attempt was made to write 36-track data on 18-track format-

 

 

 

ted medium.

 

 

4.

The tape length in the cartridge is too long or too short.

4h

HARDWARE ERROR

1.Write of buffered data failed due to a hardware failure. (Syn-

 

 

 

chronize before READ REVERSE attempted.)

 

 

2.

Error occurred when attempting to space backward over block

 

 

 

to be read.

5h

ILLEGAL REQUEST

1. Reserved bit was found set in the CDB of the READ

 

 

 

REVERSE command.

 

 

2.

SILI bit set to 1 and Fixed bit set to 1.

 

 

3.

Fixed bit is 1 but variable mode was indicated by the most

 

 

 

recent MODE SELECT

 

 

4.

The Flag bit was set but the Link bit was not set.

 

 

5.

Bytes in block could not be transferred in reverse order.

6h

UNIT ATTENTION

Indicates the READ REVERSE command was not performed due

 

 

to one of the following:

 

 

1.

The tape cartridge may have been changed.

 

 

2.

The target has been reset.

 

 

3.

The Mode parameters have been changed by another initiator.

 

 

4.

The version of the microcode has been changed (microcode

 

 

 

downloaded).

 

 

5.

A cartridge was loaded with a tape length that is too long or too

 

 

 

short.

Bh

ABORTED COMMAND

READ REVERSE command was aborted. the READ REVERSE

 

 

command can be reissued.

Dh

VOLUME OVERFLOW

Write of buffered data prior to the Read Reverse operation failed

 

 

because physical End-of-Tape has been reached.

 

 

 

 

4-82

CG00000-011503 REV. A

April 1997

Page 164
Image 164