M2488 PRODUCT GUIDE

 

DIAGNOSTIC TESTS AND ERROR CODES

Table F-15. Routine 13 - EDRC Error Detection Diagnostic Error Codes (Continued)

 

 

 

 

 

ROUTINE

TEST

TITLE

ERROR

DESCRIPTION

CODE

 

 

 

 

 

 

 

 

 

 

0x13

0x07

Write PPh host crc error check

0x01

 

Initial SPC write status is incorrect.

 

 

 

 

 

 

 

 

 

0x02

 

Error reported by Record Manager Write

 

 

 

 

 

Buffer function while attempting to write

 

 

 

 

 

EDRC non-compacted.

 

 

 

 

 

 

 

 

 

0x03

 

Incorrect SPC SCSI control signal status wait-

 

 

 

 

 

ing for REQ signal assertion.

 

 

 

 

 

 

 

 

 

0x04

 

Incorrect SPC SCSI control signal status wait-

 

 

 

 

 

ing for REQ signal deassertion.

 

 

 

 

 

 

 

 

 

0x05

 

Data transfer length error reported by SPC

 

 

 

 

 

 

 

 

 

0x06

 

SDDP failed to report expected host Packet

 

 

 

 

 

Processor CRC error.

 

 

 

 

 

 

0x13

0x08

Write PPh host count error check

0x01

 

Initial SPC write status is incorrect.

 

 

 

 

 

 

 

 

 

0x02

 

Error reported by Record Manager Write

 

 

 

 

 

Buffer function while attempting to write SG

 

 

 

 

 

EDRC non-compacted.

 

 

 

 

 

 

 

 

 

0x03

 

Incorrect SPC SCSI control signal status wait-

 

 

 

 

 

ing for REQ signal assertion.

 

 

 

 

 

 

 

 

 

0x04

 

Incorrect SPC SCSI control signal status wait-

 

 

 

 

 

ing for REQ signal deassertion.

 

 

 

 

 

 

 

 

 

0x05

 

Data transfer length error reported by SPC

 

 

 

 

 

 

 

 

 

0x06

 

SDDP failed to report expected host Packet

 

 

 

 

 

Processor error count.

 

 

 

 

 

 

0x13

0x09

Read Compression error/sgd crc-

0x01

 

Failed to receive data end-of-transfer signal in

 

 

a errors

 

 

SDDP hdxs register.

 

 

 

 

 

 

 

 

 

0x02

 

Incorrect SPC SCSI control signal status wait-

 

 

 

 

 

ing for REQ signal assertion.

 

 

 

 

 

 

 

 

 

0x03

 

Incorrect SPC SCSI control signal status wait-

 

 

 

 

 

ing for REQ signal deassertion.

 

 

 

 

 

 

 

 

 

0x04

 

Data transfer length error reported by SPC

 

 

 

 

 

 

 

 

 

0x05

 

SDDP failed to report expected data compres-

 

 

 

 

 

sion error.

 

 

 

 

 

 

 

 

 

0x06

 

SDDP failed to report expected data compres-

 

 

 

 

 

sion host count error.

 

 

 

 

 

 

 

 

 

0x07

 

SDDP failed to report expected data compres-

 

 

 

 

 

sion host CRC error.

 

 

 

 

 

 

 

 

 

0x08

 

SDDP failed to report expected CRCA error.

 

 

 

 

 

 

DIAGNOSTIC TESTS AND ERROR CODES

April 1997

CG00000-011503 REV. A

F-47

Page 447
Image 447
Fujitsu M2488 manual Diagnostic Tests and Error Codes