DIAGNOSTIC TESTS AND ERROR CODES

Table F-21. Routine 80 Test 06 - Servo FACL Error Codes in Sense Byte 19

ROUTINE

TEST

TITLE

ERROR

DESCRIPTION

CODE

 

 

 

 

 

 

 

 

 

0x80

0x06

Sense byte 19 for FACL

0x01

Door close sensor or door solenoid lock sen-

 

 

 

 

sor off error

 

 

 

 

 

 

 

 

0x02

Door solenoid lock timeout error

 

 

 

 

 

 

 

 

0x03

Door solenoid unlock timeout error

 

 

 

 

 

 

 

 

0x10

Carrier move up timeout error

 

 

 

 

 

 

 

 

0x11

Carrier move down timeout error

 

 

 

 

 

 

 

 

0x12

Carrier position sensor on too fast error

 

 

 

 

 

 

 

 

0x13

Carrier position sensor off too fast error

 

 

 

 

 

 

 

 

0x14

Carrier stopped at fault position

 

 

 

 

 

 

 

 

0x20

Catch arm open timeout error

 

 

 

 

 

 

 

 

0x21

Catch arm open sensor on too fast error

 

 

 

 

 

 

 

 

0x22

Catch arm close timeout error

 

 

 

 

 

 

 

 

0x23

Catch arm close sensor on too fast error

 

 

 

 

 

 

 

 

0x24

Catch arm open and close sensors both on

 

 

 

 

error

 

 

 

 

 

 

 

 

0x30

Mount arm move drive side timeout error

 

 

 

 

 

 

 

 

0x31

Mount arm drive end sensor on too fast error

 

 

 

 

 

 

 

 

0x32

Mount arm move magazine side timeout error

 

 

 

 

 

 

 

 

0x33

Mount arm magazine end sensor on too fast

 

 

 

 

error

 

 

 

 

 

 

 

 

0x34

Mount arm home and drive end sensors both

 

 

 

 

on error

 

 

 

 

 

 

 

 

0x35

Mount arm home and magazine sensors both

 

 

 

 

on error

 

 

 

 

 

 

 

 

0x40

No cleaning cartridge or not out of cleaning

 

 

 

 

cell

 

 

 

 

 