FAULT SYMPTOM CODES M2488 PRODUCT GUIDE
D-2 CG00000-011503 REV. A April 1997
3CCA REQ/ACK error in DATA phase, retries failed
3CCB REQ/ACK timed-out in DATA, retries failed
3CE0 Buffer error reported
3CE1 Compression error reported
3CE2 ADT timeout
3CE3 Packet Processor error
3CE4 Packet expanded greater than maximum
3CE5 Bid not found in packet group
3CE6 Unable to read packet header
3CE7 Unable to read block forward
3CE8 Unable to rewrite packet header
3CF0 ADT error
3CF1 Buffer detected error
3CF2 Compression error
Table D-2. Formatter Error Recovery
F.S.C. # DESCRIPTION E.R.P.A. BYTES
29-39
GROUP
8004 Unknown cause write trap 47 03
8170 Byte count not zero 47 03
83xx Write FMT error reg (WER not zero), xx
bit 0 - Don’t care
bit 1 - Customer data CRC error
bit 2 - CRC write error
bit 3 - DRC write error
bit 4 - VRC write error
bit 5 - Write formatter path error
bit 6 - Write trigger VRC error
bit 7 - Don’t care
22 03
8400 Can’t reset RBE 25 01
8420 Can’t detect RDEND 25 01
8440 Can’t reset WER register 25 03
8600 Can’t reset RDE, CRS or WES register 25 01
8700 PHOK time-out after DBOB (WRITE) 25 04
Table D-1. Error Recovery (Continued)
F.S.C # DESCRIPTION