FAULT SYMPTOM CODES

M2488 PRODUCT GUIDE

 

 

 

Table D-1. Error Recovery (Continued)

 

 

 

 

 

 

 

 

 

 

 

F.S.C #

 

DESCRIPTION

 

 

 

 

 

 

 

 

 

 

 

3CCA

 

REQ/ACK error in DATA phase, retries failed

 

 

 

 

 

 

 

 

 

 

 

3CCB

 

REQ/ACK timed-out in DATA, retries failed

 

 

 

 

 

 

 

 

 

 

 

3CE0

 

Buffer error reported

 

 

 

 

 

 

 

 

 

 

 

3CE1

 

Compression error reported

 

 

 

 

 

 

 

 

 

 

 

3CE2

 

ADT timeout

 

 

 

 

 

 

 

 

 

 

 

3CE3

 

Packet Processor error

 

 

 

 

 

 

 

 

 

 

 

3CE4

 

Packet expanded greater than maximum

 

 

 

 

 

 

 

 

 

 

 

3CE5

 

Bid not found in packet group

 

 

 

 

 

 

 

 

 

 

 

3CE6

 

Unable to read packet header

 

 

 

 

 

 

 

 

 

 

 

3CE7

 

Unable to read block forward

 

 

 

 

 

 

 

 

 

 

 

3CE8

 

Unable to rewrite packet header

 

 

 

 

 

 

 

 

 

 

 

3CF0

 

ADT error

 

 

 

 

 

 

 

 

 

 

 

3CF1

 

Buffer detected error

 

 

 

 

 

 

 

 

 

 

 

3CF2

 

Compression error

 

 

 

 

 

 

 

 

 

 

 

 

 

Table D-2. Formatter Error Recovery

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BYTES

 

 

F.S.C. #

 

DESCRIPTION

E.R.P.A.

29-39

 

 

 

 

 

 

GROUP

 

 

 

 

 

 

 

 

 

8004

 

Unknown cause write trap

47

03

 

 

 

 

 

 

 

 

 

8170

 

Byte count not zero

47

03

 

 

 

 

 

 

 

 

 

83xx

 

Write FMT error reg (WER not zero), xx

22

03

 

 

 

 

bit 0 - Don’t care

 

 

 

 

 

 

bit 1 - Customer data CRC error

 

 

 

 

 

 

bit 2 - CRC write error

 

 

 

 

 

 

bit 3 - DRC write error

 

 

 

 

 

 

bit 4 - VRC write error

 

 

 

 

 

 

bit 5 - Write formatter path error

 

 

 

 

 

 

bit 6 - Write trigger VRC error

 

 

 

 

 

 

bit 7 - Don’t care

 

 

 

 

 

 

 

 

 

 

 

8400

 

Can’t reset RBE

25

01

 

 

 

 

 

 

 

 

 

8420

 

Can’t detect RDEND

25

01

 

 

 

 

 

 

 

 

 

8440

 

Can’t reset WER register

25

03

 

 

 

 

 

 

 

 

 

8600

 

Can’t reset RDE, CRS or WES register

25

01

 

 

 

 

 

 

 

 

 

8700

 

PHOK time-out after DBOB (WRITE)

25

04

 

 

 

 

 

 

 

 

D-2

CG00000-011503 REV. A

April 1997

Page 382
Image 382
Fujitsu manual Fault Symptom Codes M2488 Product Guide, Table D-2. Formatter Error Recovery, 3CCA, 3CCB, Group