M2488 PRODUCT GUIDE MAINTENANCE AND SERVICING

April 1997 CG00000-011503 REV. A 8-19

8-4.3.1 Off-Line Diagnostic Menu on the Operator Panel

Table 8-17. Operator Panel Off-Line Diagnostics

COMMAND SELECTION
OR RESPONSE DESCRIPTION
*Run
Run MTC
Run MTU
Run ACL
R:###### This command begins execution of all diagnostic tests in the current test list. The
display will indicate which test is currently being executed. In the following
example, routine 0x06, test 0x03, is executing loop 0x0A.
Example: R:06030A
Run MTC - runs tests on the controller
Run MTU - runs tests on the drive
Run ACL - runs tests on the ACL
List Err ######## Lists up to the first 16 errors generated during the last Run/Continue of the cur-
rent diagnostic test list. The following example shows an error which occurred
while running routine 0x03, test 0x02 which happened to be the 5th test (node)
in the current test list:
Example: 05030102
*Continue R:###### Continue running the list of test(s) previously selected. The display is the same
as for the Run command.
RS-232 RS-232? When RS-232 is selected, all diagnostic tests are run from the Remote Mainte-
nance (RS-232) interface. Typing “quit<enter>” or pressing the RESET switch
on the Operator Control Panel will exit this mode.
*List Reg LR: #### Lists all of the tests that can be selected from the registry of diagnostic tests for a
particular diagnostic mode. The following example shows how to display the
first test of every routine in the Diagnostic Test Registry:
Example: LR: 0001
R:06030A
“Running” Routine Number
Test Number Loop count
05030102
Node Number Routine Number
Test Number Error Code
LR: 0001
“List Registry”
Routine Number
Test Number