RS-232↔IEEE 488 INTERFACE CONVERTER
| 1st Data Byte | 2nd Data Byte |
| |||
|
|
|
|
| ||
(composite) |
|
|
|
|
| |
DAV |
|
|
|
|
| |
Source |
| Valid | Not | Valid | Not | |
|
| Valid |
| Valid | ||
NFRD | All | None | All | None |
| |
Ready | Ready | Ready | Ready |
| ||
Acceptor |
| |||||
|
|
|
|
| ||
NDAC | None | All | None | All |
| |
Accept | Accept | Accept | Accept | |||
Acceptor | ||||||
|
|
|
|
|
Figure 6-2. IEEE Bus Handshaking.
6.6 Data Lines
The GPIB provides eight data lines for a
6.7 Multiline Commands
Multiline (bus) commands are sent by the Active Controller over the data bus with ATN asserted. These commands include addressing commands for talk, listen, Untalk, and Unlisten.
6.7.1 GO TO LOCAL (GTL)
This command allows the selected devices to be manually controlled. ($01)
6.7.2LISTEN ADDRESS GROUP (LAG)
There are 31 (0 to 30) listen addresses associated with this group. The 3 most significant bits of the data bus are set to 001, while the 5 least significant bits are the address of the device being told to listen.
58