10
RS-232IEEE 488 INTERFACE CONVERTER
IEEE-488 Interface
Implementation — C1, C2, C3, C4, and C28 controller subsets.
Serial to IEEE: SH1, AH1, T6, TE0, L4, LE0,
SR1, RL0, PP0, DC1, DT0, E1.
Terminators — Selectable CR, LF, LF-CR, and CR-LF
with EOI
Connector — Standard IEEE 488 connector with metric studs
Serial Interface
EIA RS-232C — AB, BA, BB, CA, CB
EIA RS-422A — Balanced voltage on TxD and RxD
Character Set — Asynchronous bit serial
Output Voltage — ±5 volts min. (RS-232C);
5 volts typical (RS-422A)
Input Voltage — ±3 volts min.; q15v max.
Baud Rate — Selectable 110, 300, 600, 1200, 1800, 2400,
3600, 4800, 7200, 9600, 19,200, and 57,600
Data Format — Selectable 7 or 8 data bits; 1 or 2 stop bits;
odd, even, mark, space, and no parity on
transmit
Duplex — Full with Echo/No Echo
Serial Control — Selectable CTS/RTS or XON/XOFF
Terminators — Selectable CR, LF, LF-CR, and CR-LF
Connector — 25-pin sub-D male, DCE configured
1. Specifications