CHAPTER 3: Getting Started

3.4 Selecting Terminator Substitution

The interface converter can be configured to provide RS-232-to-IEEE-488 and IEEE-488-to-RS-232 terminator substitution. This is useful when interfacing an RS-232 device which only issues carriage return [CR] as an output terminator to an IEEE controller which expects a carriage return followed by a line feed [CR-LF].

In a case like that, the serial terminator should be selected for CR Only while the IEEE terminator is set to CR-LF. When a serial CR character is received, it is discarded, and an IEEE CR-LF is substituted for it. In the IEEE-to-RS-232 direction, the IEEE CR is unconditionally discarded. Upon receipt of the IEEE LF, a serial CR is substituted.

The interface converter can be made totally data transparent by setting both the serial and IEEE terminators to be CR Only or LF Only.

3.4.1SERIAL TERMINATOR

SW2-3 and SW2-4 select the serial terminators for the serial input and output. The factory default is LF Only.

1 2 3 4 5 6 7 8

OPEN

CR Only

1 2 3 4 5 6 7 8

OPEN

LF Only

1 2 3 4 5 6 7 8

OPEN

LF-CR

1 2 3 4 5 6 7 8

OPEN

CR-LF

Switch

Side

View

DOT

Figure 3-8. Switch SW2: Selecting the Serial Terminator.

21

Page 21
Image 21
Black Box IC026AE-R2, IC026A-R2 manual Selecting Terminator Substitution, Switch SW2 Selecting the Serial Terminator