20
RS-232IEEE 488 INTERFACE CONVERTER
3.3.6 S
ERIAL
H
ANDSHAKE
Switch SW1-5 is used to select hardware [RTS/CTS] or software [Xon/Xoff]
serial handshake control.
With X-ON/X-OFF, the interface converter issues an X-OFF character [ASCII
value of $13] when its buffer memory is near full. When the X-OFF character
is sent, there are still more than 1000 character locations remaining to protect
against buffer overrun. When it is able to accept more information, the inter-
face converter issues an Xon character [ASCII value of $11]. The interface
converter also accepts X-ON/X-OFF on transmit from the serial host it is
communicating with. RTS/CTS serial control becomes inactive when X-
ON/X-OFF is enabled. The RTS output is, however, set to an active high
state. The CTS input is not used for this handshake and may be left
floating (unconnected).
With RTS/CTS, the interface converter un-asserts RTS (sets RTS low) when
its buffer memory is near full. When RTS is un-asserted, there are still more
than 1000 character locations remaining to protect against buffer overrun.
When it is able to accept more information, the interface converter asserts
RTS (sets RTS high). The interface converter will not transmit data to the
serial host if it detects the CTS input un-asserted (low) when configured
for this hardware handshake.
The factory-default serial control is hardware, RTS/CTS.
Figure 3-7. Switch SW1: Selecting the Serial Handshake.
Switch
Side
View
DOT
1 2 3 4 5 67 8
OPEN
RTS/CTS
1 2 3 4 5 67 8
OPEN
X-ON/X-OFF