RS-232IEEE 488 INTERFACE CONVERTER

3.7 Feature Selections

The functions of the remaining switches are dependent on the mode selected. A brief description of each of these features follows. You should refer to the listed sections for additional information.

3.7.1CONTROLLER FEATURES

In the IEEE Controller (RS-232-to-IEEE 488 Converter) mode, SW1-7 is used to determine whether the interface should, after sending the IEEE bus terminators, address the attached bus device to talk. The factory default is Talk-Back On Terminator enabled.

SW2-2 selects whether the interface converter should address the attached bus device to talk when the interface converter has nothing more to send to that device. The factory default is Talk-Back On Timeout enabled.

Refer to Chapter 4 for complete details on these features.

1 2 3 4 5 6 7 8

OPEN

Talk-Back on

Terminator Disabled

1 2 3 4 5 6 7 8

OPEN

Talk-Back on

Terminator Enabled

Switch

Side

View

DOT

Figure 3-12. Switch SW1: Enabling or Disabling “Talk Back

on Terminator” in Controller Mode.

1 2 3 4 5 6 7 8

OPEN

Talk-Back on

Timeout Disabled

1 2 3 4 5 6 7 8

OPEN

Talk-Back on

Timeout Enabled

Switch

Side

View

DOT

Figure 3-13. Switch SW2: Enabling or Disabling “Talk Back

on Timeout” in Controller Mode.

24

Page 24
Image 24
Black Box IC026A-R2, IC026AE-R2 manual Feature Selections