14
RS-232IEEE 488 INTERFACE CONVERTER

3.1 Inspection

The interface converter was carefully inspected, both mechanically and
electrically, prior to shipment. When you receive it, carefully unpack all items
from the shipping carton and check for any obvious signs of damage that may
have occurred during shipment. Immediately report any damage found to the
shipping agent. Remember to retain all shipping materials in the event that
shipment back to the factory becomes necessary.
Every interface converter is shipped with the following:
• RS-232IEEE 488 Interface Converter
• This instruction manual
• Power supply

3.2 Configuration

Three DIP switches internal to the interface converter set the configuration
of the interface.
NOTE
Selectable functions are read only at power-on and should only be set
prior to applying power to the interface. The following figures illustrate
the factory-default conditions, which are:
Serial Port: IEEE:
9600 Baud Mode = IEEE 488 Controller
8 Data Bits Address = 10
2 Stop Bits Bus Terminator = LF; EOI Disabled
No Parity Talk-Back on Terminator Enabled
Serial Terminator = LF Talk-Back on Timeout Enabled
Echo Disabled
RTS/CTS Handshake
3. Getting Started