43
Figure 4-10. Interface Converter Settings for Use with HP 7580APlotter on a Macintosh.
After configuration, turn on the plotter and the interface converter. The
interface converter’s front-panel LEDs should all light momentarily while it
performs an internal ROM and RAM test. All LEDs should go out except for
the Power and Talk LED. The Talk LED indicates that the interface converter
has detected the plotter on the IEEE bus and has addressed it to listen.
When the serial host begins to send the interface converter data, the Receive
LED will flash. If it does not, this indicates that the interface is not receiving
data from the serial host. Verify the cables are connected properly and the
serial cable wiring. Verify the serial data format, word length, stop bits and
parity.
1 2 3 4 567 8
OPEN
SW2
Mode
Talk-Back on Timeout
Serial Term
C
Enabled
CR
Switch
Side
View
DOT
Echo
Parity
No Echo
No Parity
1 2 3 4 5 67 8
OPEN
SW3
IEEE Addr
IEEE Term
EOI
5
CR
Enabled
Switch
Side
View
DOT
Switch
Side
View
DOT
1 2 3 4 5 6 7 8
OPEN
SW1
Baud Rate
Handshake
Word Length
57600
X-ON/X-OFF
7 Data Bits
Talk-Back on Terminator Enabled
Stop Bits 1 Stop Bit
CHAPTER 4: Controller Operation