RS-232IEEE 488 INTERFACE CONVERTER

 

1

2

3

4

5

6

7

8

 

SW3

 

 

OPEN

 

 

 

 

 

 

 

 

 

 

IEEE Addr

5

 

 

 

 

 

 

 

IEEE Term

CR Only

 

 

 

 

 

 

 

EOI

Enabled

 

 

 

 

 

 

 

Switch

Side

View

DOT

1 2 3 4 5 6 7 8

SW2

OPEN

Mode C

Talk-Back on Timeout Enabled

Serial Term CR

Echo No Echo

Parity Even

Switch

Side

View

DOT

1 2 3 4 5 6 7 8

SW1

OPEN

Baud Rate 9600

Handshake X-ON/X-OFF Word Length 7 Data Bits

Talk-Back on Terminator Enabled Stop Bits 1 Stop Bit

Switch

Side

View

DOT

Figure 4-6. Interface Converter Settings for Use with HP 7580A Plotter

on an IBM PC.

When using the interface converter with plotting programs on the Macintosh computer with graphic drivers such as MacPlot®, some serial data format parameters are user-modifiable. The following is a partial MacPlot config- uration screen which allows selection of baud rate, stop bits, and parity. With this driver, the word length is fixed to 7 data bits with X-ON/X-OFF serial control. These non-modifiable defaults are plotter dependent. Refer

to the plotter or driver manual for the defaults of the specific plotter. For this example, 57600 baud with one stop bit and no parity has been chosen for the serial data format.

40

Page 40
Image 40
Black Box IC026A-R2, IC026AE-R2 manual SW3